System Specification and Performance Data Sheet

Use & Care Guide

System Specification and Performance Data Sheet

Refrigerator Water Filter Cartridge Model UKF8001AXX

Specifications

Service Flow Rate (Maximum)

0.78 GPM (2 9 L/min)

PentaPure Inc.

Rated Service Life UKF8001AXX-750 (Maximum)

750 gallons/2839 liters

1000 Apollo Road

Maximum Operating Temperature

100° F / 38° C

Eagan, Minnesota 55121-2240

Minimum Pressure Requirement

35 psi /241 kPA

651 450 4913

Minimum Operating Temperature

33° F/1° C

EPA EST #35917-MN-1

Maximum Operating Pressure

100 psi / 689 kPA

100834/B

*Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of 7.5 + 0.5; temp. of 68° + 5° F (20° + 3° C)

**Measurement in Particles /ml. Particles used were 0.5 - 1 microns

*** NTU - Nephelometric Turbidity Units

General Use Conditions

Read this Performance Data Sheet and com- pare the capabilities of this unit with your actual water treatment needs.

DO NOT use this product where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. System certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

USE ONLY WITH COLD WATER SUPPLY. CHECK FOR COMPLIANCE WITH THE STATE AND LOCAL LAWS AND REGULA- TIONS.

Tested and certified by NSF International against ANSI/NSF Standards

42 & 53 in models UKF8001AXX-750 for the reduction of:

Standard No. 42: Aesthetic Effects

Standard No. 53: Health Effects

Taste and Odor Reduction

Chemical Reduction Unit

Chlorine Taste & Odor

Lead, Atrazine, Lindane, Mercury &

Mechanical Filtration Unit

Toxaphene Reduction

Particulate Reduction Class 1

Mechanical Filtration Unit

 

Cyst, Turbidity and Asbestos

 

reduction

The PuriClean® II retractable water filtration system uses a UKF8001AXX replacement cartridge. Timely replacement of filter cartridge is essential for performance satisfaction from this filtra- tion system.

Please refer to the applicable section of your Use & Care Guide for general operation, maintenance requirements and trou- bleshooting.

This system has been tested according to ANSI/NSF 42 and 53 for reduction of the substance listed above. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42 and 53.