Agilent Technologies 6811B, 6813B Description, 2. Operator Replaceable Parts, Agilent Part Number

Models: 6811B 6813B

1 91
Download 91 pages 25.18 Kb
Page 13
Image 13
Table 1-2. Operator Replaceable Parts

General Information - 1

The following table lists some common user-replaceable parts:

Table 1-2. Operator Replaceable Parts

Item

Power cord assembly Rack mount kit

4-terminal digital connector plug

Ac input safety cover (with strain relief and bushing) Screw (3), ac input barrier block (6-32 x 5/16in)

Ac output safety cover

Line fuse for Agilent 6812B (30 AM) Line fuse for Agilent 6813B (25 AM) Line fuse for Agilent 6811B (20 AM)

Screw (2), ac output safety cover (m4 x 0.7in) Screw (5), ac output barrier block (6-32 x 5/16 in) User’s Guide (this manual)

Programming Guide Quick Start Guide Quick Reference Card

Agilent Part Number

see "Options" see "Options"

1252-1488

5040-1676

N/A

5040-1704

2110-0910

2110-0849

2110-0098

0515-0053

N/A

5962-0829

5962-0889

5962-0883

5962-0885

Description

The ac source combines three instruments in one unit as shown in the following figure. The function generator produces waveforms with programmable amplitude, frequency, and shape. The power amplifier amplifies the function generator signal to produce the ac power for your application. The measurement functions range from a simple readback of rms voltage and current, to sophisticated capabilities such as waveform analysis.

DAC

SOURCE

shunt

 

WAVEFORM

BIPOLAR

MEASUREMENT

GENERATOR

AMPLIFIER

BLOCK

POWERMETER

FFT ANALYZER

Figure 1-1. AC Source Functional Elements