3 - Turn-On Checkout

 

 

 

 

Procedure

Display

 

Explanation

10.

Press Shift, and

CURR:LEV

5

Indicates the default output current limit setting.

 

Current

 

 

 

11.

Press . 5 Enter

CURR:LEV

.5

Sets the current limit to .5 amperes. The CC

 

 

 

 

annunciator is on, indicating that the unit is in

 

 

 

 

current limit mode and the light bulbs are dimmer

 

 

 

 

because the output voltage has dropped in its

 

 

 

 

attempt to limit output current.

12.

Press Protect, scroll to

CURR:PROT ON

You have enabled the overcurrent protection

 

the CURR:PROT item,

 

 

circuit. The circuit then tripped because of the

 

and press ° to select

 

 

output short. The CC annunciator turns off and

 

ON. Then press Enter.

 

 

the OCP and Prot annuciators come on. The

 

 

 

 

output current is near zero.

13.

Press Output On/Off

0.5 V 60 Hz

The output is off and the Dis annunciator turns on.

14.

Press Protect, scroll to

CURR:PROT

OFF

You have disabled the overcurrent protection

 

the CURR:PROT item,

 

 

circuit. The Prot annunciator turns off.

 

press ° to select OFF,

 

 

 

then press Enter.

15.Turn the unit off.

The next time the unit turns on it will be restored to the *RST or factory default state

In Case of Trouble

Error Messages

Ac source failure may occur during power-on selftest or during operation. In either case, the display may show an error message that indicates the reason for the failure.

Selftest Errors

Pressing the Shift and Error keys will show the error number. Selftest error messages appear as: ERROR <n>, where "n" is a number listed in the following table. If this occurs, turn the power off and then back on to see if the error persists. If the error message persists, the ac source requires service.

Table 3-1. Power-On Selftest Errors

Error No.

Error 0

Error 1

Error 2

Error 3

Error 4

Error 5

Error 6

Error 10 Error 11 to 18

Failed Test

No error

Non-volatile RAM RD0 section checksum failed Non-volatile RAM CONFIG section checksum failed Non-volatile RAM CAL section checksum failed Non-volatile RAM WAVEFORM section checksum failed Non-volatile RAM STATE section checksum failed Non-volatile RAM LIST section checksum failed

RAM selftest

DAC selftest 1 to 8