Setting the Addresses

As shown below, the E2251A has six logical address switch banks, one for each M-Module slot. You must set the logical address switches for each

M-Module installed in the E2251A Carrier.

A logical address switch bank contains eight individual switches. To determine the logical address, add together the decimal values of the switches that are set (position 1 = set, 0 = not set). For example, in the figure below, switches 4, 5, and 6 are set, the other switches are not set. The logical address is the sum of the decimal values of the set switches: 16 + 32 + 64 = 112.

Logical Address

Switch for M3

M-Module M3

M-Module M2

M-Module M1

Logical Address

Logical Address

Switch for M4

Switch for M5

M-Module M4

M-Module M5

M-Module M0

Logical Address

Switch for M0