M-Module Installation

This manual provides the following information:

Installing M-Modules in the E2251A Carrier including:

--Setting Logical Addresses

--Attaching Field Wiring and Strain Relief

--Installing RFI Dress Panels

Installing the E2251A Carrier in a VXIbus Mainframe

M-Module installation verification.

Removing M-Modules from the Carrier.

For general information about the E2251A M-Module Carrier or for M-Module programming information, refer to the E2251A M-Module Carrier User’s Manual. For information about specific M-Modules, refer to that M-Module’s User’s Manual. VXIplug&play drivers, downloadable SCPI drivers, and Soft front panels are available on the CD ROM provided with the Carrier and M-Modules. The E2251A does not support MA-Modules.

WARNING SERVICE-TRAINED PERSONNEL ONLY. The information in this manual is for service-trained personnel who are familiar with electronic circuitry and are aware of the hazards involved. To avoid personal injury or damage to the instrument, do not perform procedures in this manual or do any servicing unless you are qualified to do so.

Caution All installation, wiring, and configuration procedures in this chapter are to be done with power DISCONNECTED from the VXI mainframe and power DISCONNECTED from any external wiring/cabling. To prevent equipment damage, DISCONNECT the mainframe's power before installing any module into the mainframe.

Caution STATIC ELECTRICITY. Static electricity is a major cause of component failure. To prevent damage to the electrical components in the Carrier and the M-Modules, observe anti-static techniques when installing or removing an M-Module from the Carrier or installing or removing the Carrier from the VXI mainframe.

Caution Modules in Carrier slot M5 are restricted to 60Vdc, 30Vacrms, or 42Vacpk.

Caution Remove all packing material before installing Carrier in VXI mainframe.