Programming Reference

Store current setting

:MMEM:STOR:STAT “filename”

Syntax :MMEM:STOR:STAT “filename”

Description Stores the current setting into the specified file. If a file with the same name already exists, then this file will be overwritten.

Recall setting

:MMEM:LOAD:STAT “filename”

Syntax :MMEM:LOAD:STAT “filename”

Description Loads stored instrument setting from the given file.

All Channels

Datarate

:FREQ Syntax :FREQ?

:FREQ FE

OC3OC12OC48OC48FECFC1FC2GBE1XAUI Description Either sets or gets the instrument’s datarate. The datarate

always applies to all the channels (electrical out, optical out, clock out, and error detector input).

Available Data Rates

Name

Frequency

Parameter

 

Fast Ethernet

125.00Mb/s

FE

 

OC-3

155.52Mb/s

OC3

 

OC-12

622.08Mb/s

OC12

 

OC-48

2.48832Gb/s

OC48

 

OC-48 with

2.666Gb/s

OC48FEC

 

FEC

 

 

 

1 x FC

1.0625Gb/s

FC1

 

2 x FC

2.125Gb/s

FC2

 

Gigabit

1.25Gb/s

GBE1

 

Ethernet

 

 

 

XAUI

3.125Gb/s

XAUI

N5980A User Guide