Commissioning

ACT 250 controller electrical connections

ATP 150 or ATP 400 pump

If the controller is remote controlled, make the various connections on the REMOTE connector (see page 13 for wiring details).

If the controller is used in local mode, the

pump can only operate if the connector plug (ordered separately) is connected to the REMOTE

connector (see page 13 for wiring details).

PC

Connect the fan (air-cooled ATP)

Connect the controller to the pump using the cable (ordered separately)

RS configuration

Remote cable

or

Connector plug (standard wiring) to use the unit in local mode.

Connect the RS232/485 serial link cable to the connector (cable and PC supplied by customer)

January 2001

Connect the controller to the mains (cable ordered separately).

An earth connection must be provided.

10

Alcatel Vacuum Technology France - ACT 250 addendum

Page 11