Commissioning

Detailed description of RS commands

DLI Defines the DataLogger transmission interval

Syntax #adrDLIxxx<CR>[<LF>]

xxx:DataLogger transmission interval in seconds condition: 001 xxx 255

Result #adr,ok or Err2

See also: DLR Note: if ok, the interval sent is stored in user memory.

DLR

 

Enables DataLogger operation (RS232 only)

Syntax #adrDLR<CR>[<LF>]

Result #adr,sssss,nnnnn,iiii,ttttt,uuuu.o,www,ppp,vvv

Returns current values

:

sssss: current speed (rpm)

nnnnn: speed set point (rpm)

iiii: current value (mA)

ttttt: pump operating time (hours) uuuu.o : (reserved)

www: pwm (reserved)

ppp: pump temperature (°C)

vvv: variator temperature (°C)

The main characteristics of the pump and its controller are sent over the RS link, at the rate defined by the DLI command.

See also: DLI, LNG, SEP, SHT Note: any new characters arriving on the serial port (RS 232) will cancel the automatic DataLogger transmission.