Commissioning

Detailed description of RS commands

OPT

Syntax

Result

See also: SEL

RPM

Syntax

Result

See also: NSP, SBY

SAV

Syntax

Result

Used to select possible user choices

#adrOPT2 n<CR>[<LF>]

choice of temperature unit:

n = 0 : degrees Centigrade

n = 1 : degrees Fahrenheit

#adr,ok

Comment: The choice of the temperature unit affects the results of the DLR and STA strings.

Defines the speed set point in stand-by mode

#adrRPM nnnnn<CR>[<LF>] or #adrRPMnnnnn<CR>[<LF>]

#adr,ok or #adr,ErrX

X = 1, out of range; 2, parameters ; 3, context (not in Stand-by mode)

Comment: if ok, the new speed is automatically stored in user memory.

Saves the internal parameters in user memory

#adrSAV<CR>[<LF>]

#adr,ok

Saves the current context (except for running-in cycles). If this command is sent when the pump is powered up, it can for example allow automatic re-start in the event of a power cut.

January 2001

20

Alcatel Vacuum Technology France - ACT 250 addendum

Page 21
Image 21