The Alarm Setup Window

 

FRS-1002-MD / FRS-1002-MD-LG-PA

Guide to installation and operation

 

 

 

The Alarm Setup Window

Alarms reported to Dashboard

Alarms reported to card’s LED

Card status (DS1) Manual backgroundManual backgroundManual backgroundManual backgroundManual background

Input 1(DS2)

Input 2 (DS3) Manual backgroundManual backgroundManual backgroundManual backgroundManual background Not used (DS4) Manual backgroundManual backgroundManual backgroundManual backgroundManual background Not used (DS5) Manual backgroundManual backgroundManual backgroundManual backgroundManual background

Card Reference (DS6) Manual backgroundManual backgroundManual backgroundManual backgroundManual background

FRS - 1002 - MD

Problems detected by the FRS-1002 card are transmitted as alarms to the card’s LED, to the Dashboard interface, and to the optional SNMP monitoring. The problems detected can be reported to the user as minor alarms or critical alarms.

The Alarm Setup window allows the user to set the alarm level at which many types of errors will be reported to the LEDs or to Dashboard, independently for channel 1 and 2, for the reference signal and for the license key detection. The alarm signals can also be disabled.

Minor: When the alarm level for a specific type or error is set to minor, the card’s LED will report the problem with a yellow light and Dashboard with a yellow circle next to an error message describing the problem.

Critical: When the alarm level for a specific type or error is set to critical, the card’s LED will report the problem with a red light and Dashboard with a red circle next to an error message describing the problem.

Carrier and video detection errors on input 1 are always reported as critical and cannot be set otherwise.

The Alarm Setup settings are automatically saved to memory and are recalled after a power-up.