Ignition Control Operation
Diagnostic LED (DGN LED) / Error CodesThe Diagnostic LED or DGN LED is located by the power connector on the ignition control. Refer to Figure 23. The Diagnostic LED will indicate the status of the ignition control. Refer to Table 3.
Installation/Operation Supplement
The Diagnostic LED will flash error codes one half second on and one half second off. Error codes are separated by a one second pause before the code is repeated.
LED Color | Description |
|
|
Initialization | |
|
|
Green | Standby / Normal Operation |
|
|
Red | Fault Indication Code |
|
|
Table 3
Error |
|
|
|
| DGN LED status |
|
| Fault Type | |||||
Code |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
| Red |
|
| Ignition Control Internal Failure | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
| 2 Red Flashes |
|
| Gas Valve Not Connected | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
| 3 Red Flashes |
|
| Ignition/Flame Sense Failure | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
| 4 Red Flashes |
|
| Reset Switch is Shorted | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
| Slow Red and Green Flashes |
|
| Low Voltage Detection | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
| Fast Red and Orange Flashes |
|
| Ignition Control is in Reset Delay | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TMB2176N
1Diagnostic (DGN) LED
Figure 23
70278501 (EN) | © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT | 29 |