| Installation/Operation Supplement | ||
Installation |
|
| ||
Specifications and Dimensions |
|
|
|
|
|
|
|
|
|
Specifications |
| 50 Pound |
| 75 Pound |
|
|
|
|
|
Noise level measured during operation at |
| 63 dBA |
| 69 dBA |
operator position of 1 meter (3.3 feet) in front |
|
|
| |
of machine and 1.6 meters (5.2 feet) from |
|
|
|
|
floor. |
|
|
|
|
|
|
|
|
|
Net Weight (approximate): |
| 247 |
| 279 |
kg (lbs.) |
| (545) |
| (615) |
|
|
|
|
|
Cylinder Size: |
| 940 x 762 |
| 940 x 914 |
mm (in.) |
| (37 x 30) |
| (37 x 36) |
|
|
|
|
|
Cylinder Capacity (dry weight): |
| 22.7 |
| 34 |
kg (lbs.) |
| (50) |
| (75) |
|
|
|
|
|
Air Outlet Diameter: |
| 203 |
| 203 |
mm (in.) |
| (8) |
| (8) |
|
|
|
|
|
Maximum Static Back Pressure: |
| 1.3 |
| 1.3 |
mbar (W.C.I.) |
| (0.5) |
| (0.5) |
|
|
|
| |
Maximum Airflow: |
| 354 | Gas/Steam 50 Hz 354 (750) | |
| (750) | Gas/Steam 60 Hz 434 (920) | ||
L/sec. (C.F.M.) |
| |||
|
| Electric | 354 (750) | |
|
|
| ||
|
|
|
|
|
Motor Horsepower: |
| 1/2 |
| 3/4 |
Nonreversing |
|
| ||
Reversing |
|
|
|
|
Fan |
| 1/3 |
| 1/3 |
Cylinder |
| 1/3 |
| 1/3 |
|
|
| ||
|
|
|
|
|
| Gas Models |
|
| |
|
|
|
|
|
Gas Connection |
| 1/2 in. NPT |
| 1/2 in. NPT |
|
|
|
|
|
Gas Burner Rating: |
| 126.6 |
| 174.1 |
Mj/hr (Btu/hr) |
| (120,000) |
| (165,000) |
|
|
|
|
|
| Electric Models |
|
| |
|
|
|
|
|
Heating Elements Rating: |
| 21 kW (240 V/50 Hertz) |
| 30 kW |
Kilowatts (kW) |
| 30 kW (other voltages) |
|
|
|
|
|
|
|
| Steam Models |
|
| |
|
|
|
|
|
Steam Connection |
| 3/4 in. NPT |
| 3/4 in. NPT |
|
|
|
|
|
Steam Coil Rating: |
| 5.1 |
| 6.1 |
Btu/hr (Boiler Horsepower) |
| (177,500) |
| (210,300) |
|
|
|
|
|
70278501 (EN) | © Published by permission of the copyright owner – DO NOT COPY or TRANSMIT | 7 |