Programming
To Edit an Entire Wash Cycle Formula
1.Enter PROGRAM Mode. Refer to Entering Program Mode.
2.Press the (∧) keypad until display shows “CY01”.
3.Press the (∧) or (∨) keypad until cycle to be edited is displayed.
4.Press START (Enter) keypad to select the cycle desired. Refer to Figure 3, showing which cycle number corresponds to each keypad when in RUN Mode.
Agitation for the cycle
5.With display showing “CY_x” (x = cycle number), press the START (Enter) keypad.
6.Display shows either “norn” (for normal agitation), or “GEnt” (for gentle agitation). Refer to Table 3.
7.Press the (∧) or (∨) keypad to alter the selection, or the START (Enter) keypad to continue.
Display | Meaning |
|
|
norn | 12 seconds forward, 3 seconds pause, |
| 12 seconds reverse, 3 seconds pause, and |
| repeat for programmed time. |
|
|
GEnt | 3 seconds forward, 12 seconds pause, |
| 3 seconds reverse, 12 seconds pause and |
| repeat for programmed time |
|
|
| Table 3 |
Wash 1 – Wash 4
NOTE: Programming a time other than “00” for Wash 1 will make the WASH indicator LED light while this step is running, but NOT in PROGRAM Mode.
8.The main display shows “USH1” indicating you are in the Wash segment (number will reflect selected Wash cycle
9.Press START (Enter) keypad. Display shows agitation time during the step: “00” (skips segment) or
10.Press the (∧) or (∨) keypad to alter the selection, or the START (Enter) keypad to continue.
11.Display shows “CFIL”, “HFIL”, “bFIL” or “EFIL” for Cold, Hot, Both (warm) or Extra fill, respectively.
12.Press the (∧) or (∨) keypad to alter the selection, or the START (Enter) keypad to continue.
NOTE: Extra fill (“EFIL”) is possible only if configured for “EFIL” in SETUP Mode. If model is not configured for the extra fill valve, “nEFL” will display. If configured, a third valve can be controlled.
13.Display shows “LO”, “nEd”, or “HI” for Low, Medium, or High water level, respectively.
14.Press the (∧) or (∨) keypad to alter the selection, or the START (Enter) keypad to continue.
15.Display shows “SUP0”, “SUP1”, “SUP2”, “SUP3”, or “SUP6” (or “S 12” depending on version of control). Refer to Table 2 for operation of each supply selection.
16.Press the (∧) or (∨) keypad to alter the selection, or the START (Enter) keypad to continue.
NOTE: If programmed for “SUP2”, the ADD BLEACH indicator LED light turns on and is set up for “bEEP” the buzzer sounds for the first eight seconds Supply 2 is on.
Heated Models Only
17.Display shows temperature in degrees F or C. Display will show degrees F if configured for “FAr” in SETUP Mode, or degrees C if configured for “CEL” in SETUP Mode. Range is 80°F to 205°F, or 00F (no heat for segment), or 27°C to 95°C, or 00C (no heat for segment).
WARNING
To prevent personal injury, avoid contact with inlet water temperatures higher than 125° Fahrenheit (51° Celsius) and hot surfaces.
W748
18.Press the (∧) keypad to increase, or (∨) keypad to decrease temperature in
The control will energize heat and pause cycle timing for up to 40 minutes until the programmed temperature is first reached.
24 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232157 |