Software Version sb275a05 17
Version sb275a05
C613-10464-00 Rev H
CR00010052 Switch 2 The maximum number of IP interfaces that can be defined on a line card
switch instance is 60. An incorrect error message was displayed when
more than 60 IP interfaces we re defined on a line card switch instan ce.
This issue has been resolved.
CR00010765 SYSR 2 Previously, the switch incorrectly allowed users to enable features on the
master controller when the slave controller did not have a matching
licence. This meant that the slave and the master could not synchronise.
This issue has been resolved. Attempting to enable a feature on the
master controller now gives an error if the slave controller does not have
a matching licence for that feature.
CR00010996 Port
Authentication
2When port authentication was using a RADIUS server, it sometimes
stopped working after several hours. This was because port
authentication generated RADIUS Accounting Request (STOP) messages
with an incorrect Acct-Session-Time value.
This issue has been resolved.
CR00011002 TCP 2 When loading a file using the HTTP method, occasionally the file would
not load if too many out of sequence TCP packets were received.
This issue has been resolved.
CR00011247 GUI Agent 2 Previously, using the GUI to configure the output log caused the switch to
reboot.
This issue has been resolved.
CR00011273 SYSR 2 When Flash memory on the master switch controller contained many
large files, SYSR s ometimes reset itself p rematurely.
This issue has been resolved.
CR00011337 Environment
Monitoring
2Previously, the switch did not record the system temperature, and
therefore output of the command show system displayed the
temperature as 0°C.
This issue has been resolved.
CR00011485 SYSR 2 Previously, enabling health checks and setting time3action to blade
could cause the switch to reboot. This happened if a web browser was
also connected to the GUI.
This issue has been resolved.
CR00011600 GUI Agent 2 Previously, the GUI’s “Restore Configuration” functionality did not
operate correctly.
This issue has been resolved.
CR00011822 HTTP Server 2 When loading a file via HTTP, the switch sometimes rebooted.
This issue has been resolved.
CR00011880 GUI 2 Using the GUI to configure STP ports caused the switch to reboot.
This issue has been resolved.
CR Module Level Description