Software Version sb275a05 9
Version sb275a05
C613-10464-00 Rev H
Level 4
CR00013048 Firewall 3 When IP NAT or firewall NAT was used, the switch s ometimes generated
ICMP messages that specified the wrong source IP address. This meant
that the response to traceroute could be incorrect.
This issue has been resolved.
CR00014021 Switch 3 In certain circumstances, if the switch was configured with IP filters and
STP, then some traffic would be incorrectly blocked.
This issue has been resolved.
CR Module Level Description
CR Module Level Description
CR00002394 IP Gateway 4 RIP would try to send route update packets when the lower link layer was
down.
This issue has been resolved, so that RIP no longer tries to send packets
when the lower link layer is down.
CR00008006 OSPF 4 Previously, the maximum metric value for OSPF route redistribution was
16777215. This has been changed to 16777214.
CR00010399 IP Gateway 4 Previously, the ? help for some IP commands showed duplicate options.
This issue has been resolved.
CR00010540 TTY 4 Sometimes, output from the CLI ? help is long enough for the page
scrolling mechanism to take effect. This produces the prompt:
--More-- (<space> = next page, <CR> = one line, C = continuous, Q = quit)
Previously, if a user entered q in response to this prompt, the command
was lost instead of regenerated.
Also, commands terminated with the ? or Tab characters were a dded to
the command history with the ? or Tab character present, which is not
desirable behaviour.
These issues have been resolved.
CR00010584 OSPF 4 The “operation successful” message was not produced after the
command reset ospf spf was successfully carried out.
This issue has been resolved.
CR00011743 Core, GUI 4 The GUI sometimes displayed a value above 100% for the peak utilisation
of a port.
This issue has been resolved.
CR00012192 Core, Utility 4 If the ? is entered at the end of an incomplete command (to obtain help),
but the partially-entered command contains an error, then an error
message is displayed.
Previously, the incomplete command was not t hen re-presented to the
user for editing.
This issue has been resolved, so that the incomplete command is now
presented to the user again after the error message.