18 Features in sb275a01 Software Maintenance Release Note
Version sb275a05
C613-10464-00 Rev H
Level 3
Level 4
Enhancements
CR Module Level Description
CR00007863 IPv4 ICMP 3 Previously, SwitchBlade v2 linecards did not generate an ICMP redirect
message in response to the first ICMP request they received.
This issue has been resolved.
CR00011316 Operations 3 Previously, entering the command set summertime could cause extra
digits to appear in the output of the commands show ip interface and
show config dynam=trigger.
This issue has been resolved.
CR00011339 Port Trunking 3 The command create switch trunk appeared twice in the configuration
file created by the command create config—in both the switch pre-VLAN
and post-VLAN sections.
This issue has been resolved, so that the command now only appears in
the post-VLAN section.
CR00011480 DHCPv4 Server 3 BOOTP Relay and the DHCP server cannot operate at the same time.
Previously, if an attempt was made to enable one of these services and the
other service was already operational, the second service was made
operational. The first service stopped operating, but the switch did not
report this.
Now, the switch reports an error instead of enabling the second service.
CR Module Level Description
CR00011127 SYSLOG 4System log messages of type “switch” are now indicated by the number
3 and the text “SWI”, as shown in bold in the following example:
09 10:27:05 3 SWCX SWI SILIC Soft reset on Po rt 2.3
CR00011184 HealthCheck 4The command show switch loopdetection now shows all ports in both
the LDF Method and BCCOUNTER Method sections of the output.
Previously, the BCCOUNTER Method section only showed the ports for
which loop=bcc was enabled.
CR00011651 Board Hotswap
4When the command reset switch blade was entered with a blade
number that was too high, the error message sometimes said that the
maximum blade value was 10.
The error message now correctly says that the maximum blade value is 8.
CR Module Level Description
CR00011621 SYSR -The show sys sysr slave command now shows the slave switch
controller’s synchronisation status and the last event that occurred on the
slave controller. This information is updated every 5 seconds.