ENABLE IP ICMPREPLY

Patch 86253-07 For Rapier Series Switches

SHOW IGMPSNOOPING ROUTERADDRESS

29

If ALL is specified, all configurable ICMP message replies are disabled. If NETUNREACH is specified, all network unreachable message replies are disabled (RFC792 Type 3 Code 0). If HOSTUNREACH is specified, all host unreachable message replies are disabled (RFC792 Type 3 Code 1). If REDIRECT is specified, all ICMP redirect message replies are disabled (RFC792 Type 5 Code 0, 1, 2, 3).

Example To disable all configurable ICMP messages, use the command:

DISABLE IP ICMPREPLY=ALL

See Also ENABLE IP ICMPREPLY

DISABLE IP ECHOREPLY

SHOW IP ICMPREPLY

ENABLE IP ICMPREPLY

Syntax ENABLE IP ICMPREPLY[={ALLNETUNREACHHOSTUNREACHREDIRECT}]

Description This command enables ICMP reply messages.

If ALL is specified, all configurable ICMP message replies are enabled. If NETUNREACH is specified, all network unreachable message replies are enabled (RFC792 Type 3 Code 0). If HOSTUNREACH is specified, all host unreachable message replies are enabled (RFC792 Type 3 Code 1). If REDIRECT is specified, all ICMP redirect message replies are enabled (RFC792 Type 5 Code 0, 1, 2, 3).

Example To enable all configurable ICMP messages, use the command:

ENABLE IP ICMPREPLY=ALL

See Also ENABLE IP ECHOREPLY

DISABLE IP ICMPREPLY

SHOW IP ICMPREPLY

SHOW IP ICMPREPLY

Syntax SHOW IP ICMPREPLY

Description This command display the status of configurable ICMP messages (Figure

Figure 2: Example output from the SHOW IP ICMPREPLY command:

SHOW IP ICMP REPLY MESSAGES

--------------------------------------------------------------------------------

ICMP REPLY MESSAGES:

 

Network Unreachable

disabled

Host Unreachable

disabled

Redirect

enabled

--------------------------------------------------------------------------------

Patch 86253-07 for Software Release 2.5.3 C613-10382-00 REV E