Allied Telesis AR400 manual Default Timeout Interval = 2*130 + 100/10 = 270 seconds

Models: AR400

1 110
Download 110 pages 38.09 Kb
Page 79
Image 79

Configurable IGMP timers and counters > Default Timeout Interval

Defaults First, the following output shows the default settings.

Manager Switch 1> show ip igmp

IGMP Protocol

------------------------------------------------------------------------

Status

Enabled

Default Query Interval

125

secs

Default Timeout Interval

260

secs

Last Member Query Interval

10 (1/10secs)

Last Member Query Count

2

 

Robustness Variable

2

 

Query Response Interval

100

(1/10secs)

.

 

 

.

 

 

.

 

 

Increase

Default

Query

Interval

The Default Timeout Interval = (2*125) + (100/10) = 260 seconds.

Next, change the Default Query Interval to 130 seconds.

Manager Switch 1> set ip igmp queryinterval=130

Info (1005003): Operation successful.

Manager Switch 1> show ip igmp

IGMP Protocol

------------------------------------------------------------------------

Status

Enabled

Default Query Interval

130

secs

Default Timeout Interval

270

secs

Last Member Query Interval

10 (1/10secs)

Last Member Query Count

2

 

Robustness Variable

2

 

Query Response Interval

100

(1/10secs)

.

 

 

.

.

The Default Timeout Interval = (2*130) + (100/10) = 270 seconds.