Allied Telesis AT-9900 Series manual CR00011995, show log type=55 subtype=backoff, CR00012043

Models: AT-9900 Series

1 54
Download 54 pages 47.42 Kb
Page 24
Image 24

 

 

 

 

 

 

 

Features in 276-02

 

 

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

Module

Level

Description

AR44x / AR450

AR7x5

AR750S

 

Rapier i

AT-8800

AT-8600

 

AT-8700XL

AT-8948

AT-9900

AT-9800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00011995

BGP

4

To simplify displaying BGP memory usage, the command show bgp memlimit

Y

Y

Y

 

Y

Y

-

 

-

Y

Y

Y

 

 

 

bgp has been removed. Use the command show bgp memlimit scan instead.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Also, you can now display only the BGP backoff log messages by using either of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the following commands:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

show log type=55 subtype=backoff

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

show log type=55 subtype=7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR00012043

BGP

4

When a user entered conflicting values for BGP backoff thresholds (the backoff

Y

Y

Y

 

Y

Y

-

 

-

Y

Y

Y

 

 

 

and low parameters of the set bgp backoff command), the error message did

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

not adequately show the dependency between these two parameters.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This issue has been resolved. The error message now reads (for example):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error (3103332): BACKOFF parameter value 90 too low; must be greater than

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW parameter value 94.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version 276-03

C613-10474-00 REV B

Page 24
Image 24
Allied Telesis AT-9900 Series manual CR00011995, show log type=55 subtype=backoff, show log type=55 subtype=7, CR00012043