How to Start an AT-GS950/8 WEB Management Session
Configure
Factory Default
Values
Figure 14. Factory Default Reset/Reboot Page
3.Go to the lower part of the page to the Reboot section.
4.In the Reboot Type field, select Normal from the pull-down menu. When the switch is rebooted with this selection, all configuration parameters that are saved in flash memory are loaded into the switch’s active memory.
Note
Two additional options are available in the Reboot Type field. The procedures for these options are described in "Configure Factory Default Values".
5.Click Apply.
The switch immediately begins to reload the AT-S107 Management software and configuration parameters. This process takes approximately two minutes to complete. You can not manage the device during the reboot. After the reboot is finished, you can log in again if you want to continue to manage the switch.
This procedure returns all AT-S107 Management software parameters to their factory default values and deletes all tagged and port-based VLANs on the switch.
Note
The AT-S107 Management software default values are listed in the AT-GS950 Web User Guide..
32