18.[MjCn]

This command selects the matrix to be active.

Command Format: [MjCn]

j = Matrix ID (j = # from 1 to 9)

Cn = Card ID (n = slot # from 1 to max slots)

Example:

There is a Matrix Engine in slot 8. Send the command [M1C8] to recall the Matrix 1 configuration of C8.

RECALL MATRIX ON POWER-UP

In order to make Matrix 1’s configuration the default when power is turned on, send the

Example 2: [MAT1;16;16;00;00;02;00;C8S]

Inputs = 16

Outputs = 16

Input Offset = 00

Output Offset = 00

Width = 02

Spacing = 00

In this configuration, if Input 1 is connected to Output 16, the entire channel, 1a and 1b, will be switched to outputs 16a and 16b respectively.

[M1C8S]. The feedback will be similar to:

[SAVED]

19.[MODE]

This command sets the matrix switch mode to blocking or non-blocking. See the following examples for command functionality.

Command Format: [MODEmCn]

m = 1 = ON, 0 = OFF

Cn = Card ID (n = slot # from 1 to max slots)

Input Cards

4

3

2

1

13a

9a

5a

1a

 

 

 

 

13b

9b

5b

1b

 

 

 

 

14a

10a

6a

2a

 

 

 

 

14b

10b

6b

2b

 

 

 

 

15a

11a

7a

3a

 

 

 

 

15b

11b

7b

3b

 

 

 

 

16a

12a

8a

4a

 

 

 

 

16b

12b

8b

4b

 

 

 

 

Output Cards

1

2

3

4

1a

5a

9a

13a

 

 

 

 

1b

5b

9b

13b

 

 

 

 

2a

6a

10a

14a

 

 

 

 

2b

6b

10b

14b

 

 

 

 

3a

7a

11a

15a

 

 

 

 

3b

7b

11b

15b

 

 

 

 

4a

8a

12a

16a

 

 

 

 

4b

8b

12b

16b

 

 

 

 

Example: NON-BLOCKING

Send the command [MODE0C8] to turn off blocking for the engine in slot 8. Next, send the command [I1O*C8] to connect Input 1 to all outputs. In non-blocking mode, the inputs will be switched and the outputs will be enabled.

Example: BLOCKING ON

Send the command [I1O*C8] to connect Input 1 to all outputs. With blocking on, Input 1 will be connected to all outputs, but only output 1 will be enabled. The remaining outputs will need to be enabled using the [ON] command.

Connecting a single output results in the output being switched and enabled. For example, sending [I22O22C8] with blocking on results in Input 22 being connected to Output 22, with Output 22 being enabled.

400-0367-005

16

Page 17
Image 17
Altinex MT107-103 manual MjCn, Recall Matrix on POWER-UP, Mode