MULTITASKER™

PATH OPERATION

The path for outputs on the same or multiple cards may be preloaded. This will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in ‘P’ are not executed immediately.

Command Format: [ONmCnUiP]

m = Output No. (m = # from 1 to 8)

Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

P= Path

Example:

An MT110-103card is in slot 4 and another in slot 8. Enable Output 1 of C4 and Output 3 of

C8 simultaneously by sending the following:

[ON1C4P]

[ON3C8P]

[SW]

If "F" is included, use the [ONmCnPF] command or the [ONmCnFP] command.

FEEDBACK OPERATION

After processing a command, an “OK” or “[ERR001]” will be returned as feedback if ‘F’ is included at the end of a command string.

Command Format: [ON…..F]

Example:

[ON1C2F]: if path is not set

[ON1C2PF]: if path is set

9.[OFF]

This command disables one or all outputs of a single card or a group of cards.

SINGLE CARD OPERATION

Command Format: [OFFmCnUi]

m = Output No. (m = # from 1 to 8)

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Card 5 has Output 1 on. The following commands may be used to turn off the input.

1)

[OFF1C5]:

Turns off only Output 1.

2)

[OFFC5]:

Turns off all outputs.

GROUP OPERATION

This command disables output ‘m’ for each card in group ‘k’ of unit ‘i’.

Command Format: [OFFmGkUi]

m= Output No. (m = # from 1-8, * for all) Gk = Group ID (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

1.[OFF1G1]: Turns off Output 1 for each card in Group 1.

2.[OFFG1]: Turns off all outputs for each

card in Group 1.

PATH OPERATION

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card may be preloaded.

Command Format: [OFFmCnUiP]

m= Output (m = # from 1 to 8, * for all) Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

P= Path

Example:

There are two MT110-103cards in slots 4 and

8.Disable Output 1 of card 4 and Output 3 of card 8 simultaneously using the following commands:

[OFF1C4P]

[OFF3C8P]

[SW]