Altinex MT110-101 manual STA1, STA0, MT110-103 card, Group Operation

Models: MT110-101

1 26
Download 26 pages 51.44 Kb
Page 12
Image 12

MULTITASKER™

The matrix I/O connections are also read left to right representing outputs 1-8 and the input to which each is connected. The first two digits show the input number to which Output 1 is connected. The third and forth digits are for Output 2 and so on.

The matrix configuration shows the current configuration of the matrix, either 16x8, 8x4 or 4x2.

The output volume levels are read the same as the matrix connections. The first two digits are the volume level for Output 1, the third and forth are for Output 2 and so on.

The mute status is either a ‘1’ or a ‘0’. A ‘1’ indicates the card outputs are muted. A ‘0’ means the outputs are on.

6.[STA1]

This command enables automatic feedback from the front panel. The command affects any card with auto-feedback capability, not just the MT110-103.The default at power on or reset is STA0, off. For more details, see the [?Cn] command definition.

Command Format [STA1] = On

Feedback Prefix Definitions:

MT

Card Model Number

VR

Firmware Revision

ON

Output On/Off Status

MA

Matrix Connections

MX

Matrix Configuration

VO

Output Volume

MU

Mute On/Off

Example 1:

Command = [I2O*C4] Feedback = (MA020202…C04)

MA = Matrix Connections

0202.. = Input 2 to Output 1 Input 2 to Output 2 etc…

C04 = Card/Slot number

7.[STA0]

This command disables automatic feedback from the card and front panel. The command affects any card with auto-feedback capability, not just the MT110-103.The default at power on or reset is STA0, OFF.

Command Format [STA0]

8.[ON]

This command will enable an output of a single card, or a group of cards.

SINGLE CARD OPERATION Command Format: [ONmCnUi]

m = Output No. (m = # from 1 to 8)

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

There is an MT110-103card in slot 5. All of the outputs on the card are off.

1)

[ON1C5]:

Turns on only Output 1 of the

 

 

MT110-103 card.

2)

[ONC5]:

Turns on all outputs of the

 

 

MT110-103 card.

GROUP OPERATION

This command enables output ‘m’ for each card in group ‘k’ of unit ‘I’.

Command Format: [ONmGkUi]

m= Output number (m = # from 1-8) Gk = Group number (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

[ON1G1]: Turns ON Output 1 for each card in Group 1. See the GROUP commands for a detailed explanation.

400-0197-005

11

Page 12
Image 12
Altinex MT110-101 manual STA1, STA0, MT110-103 card, Group Operation