Altinex MT110-101 manual Troubleshooting Guide

Models: MT110-101

1 26
Download 26 pages 51.44 Kb
Page 24
Image 24

MULTITASKER™

32)

[ + ]

Increment volume

33)

[ - ]

Decrement volume

34)

[RUP]

Ramp UP to max (32)

35)

[RDN]

Ramp DOWN to mon (0)

36)

[RUPm]

Ramp volume UP to max (32)

37)

[RUPm=]

Ramp volume UP to a value

38)

[RDNm]

Ramp volume DOWN to min (1)

39)

[RDNm=]

Ramp volume DOWN to a value

40)

[RST]

Stop ramping

41)

[RAMP]

Display ramp rate

42)

[RAMP=]

Set ramp rate

43)

[MUT0]

Output Volume ON

44)

[MUT1]

Output Volume OFF

45)

[MAT]

Matrix Configuration

46)

[HELP]

Display available commands

TROUBLESHOOTING GUIDE

8

We have carefully tested and have found no problems in the supplied MT110-101/103; however, we would like to offer suggestions for the following:

8.1 LED IS NOT LIT

Cause 1: Card cage is not plugged in.

Solution: Plug card cage in. If the LED lights, the problem is solved. If the LED is still not ON, see Cause 2.

Cause 2: Card is not plugged in all the way.

Solution: Push the card in all the way. If the LED is still not ON, see Cause 3.

Cause 3: Card cage slot has a problem.

Solution 1: Test the card in other slots of the card cage. If the slot was damaged, the card may work in other slots. If other slots work and the LED lights, the problem is the card cage slot. The card cage may require service. Call ALTINEX at (714) 990-2300. If the other slots do not work and the LED is still not lit, see Solution 2.

Solution 2: Take any other known good card with an LED and verify that the slot used is good by seeing if the other card’s LED lights in that slot. If it lights, then the original card may be the source of the problem. Call ALTINEX at (714) 990-2300.

8.2 LED IS BLINKING RED

Cause 1: The CPU on the card is not working properly.

Solution 1: Look at the card and verify that there is no damage. If there is no damage, see Solution 2.

Solution 2: Verify that all IC’s are seated in their sockets. If the LED is still blinking red, see Cause 2.

400-0197-005

23

Page 24
Image 24
Altinex MT110-101 manual Troubleshooting Guide