Installation
STEP 3: PREPARE THE VENTING BLOWER
blower plate mounting
blower unit
exhaust | port., |
st | _" blower unit |
ports | mountingscrew |
| |
Figure 15 | Figure 1613 |
ROOM-VENTED (Recirculating)
INSTALLATION:
blower
1.Remove one blower unit mounting screw and two blower plate screws. Remove the blower pJate from cabinet. See Figure 17.
2.Carefully lift the blower unit out of the microwave oven.
3.Rotate blower unit 90" so the exhaust ports face the front of the cabinet. See Figure 18.
4.Place the blower unit back into the microwave oven.
5.Reattach blower plate to microwave oven. Attach with one blower unit mounting screw and then two blower plate mounting screws. See Figure 19.
screws
blower unit mounting screw
Figure 17
I screws
| blower unit |
| mountingscrew |
Figure 18D | Figure 19 |
|