Amana XRSS287BW, XRSS287BB manual Water Filter Data, Specifications

Models: XRSS287BB XRSS287BW

1 280
Download 280 pages 29.59 Kb
Page 22
Image 22

Water Filter Data

® System Specification and Performance Data Sheet

Refrigerator Water Filter Cartridge Model WF50

Specifications

Service Flow Rate (Maximum)

0.75 GPM (2.83 L/min)

Rated Service Life WF50-NI300 (Maximum)

300

gallons/ 1135 liters

3HUIRUPDQFH￿'DWD￿

 

 

Rated Service Life WF50-WI500 (Maximum)

500

gallons/ 1892 liters

Maximum Operating Temperature

100° F/38° C

Minimum Pressure Requirement

35 psi/ 138 kPa

Maximum Operating Pressure

120 psi/ 827 kPa

General Use Conditions: Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs.

O NOT use this product where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. System certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

The Amana® Clean ’n Clear™ retractable water filtration system uses a WF50 replacement cartridge (see Amana® contact information at the front of your manual to order). Timely replacement of filter cartridge is essential for performance satisfaction from this filtration system. Please refer to the applicable section in this Owner's Manual for general operation, maintenance requirements and troubleshooting.

This systems has been tested according to ANSI/NSF 42 and 53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANS /NSF 42 and 53.

 

 

 

Average

 

 

 

 

Influent

Effluent

%

Maximum

Min. Required

Inlet

Substance

Water

Average

Reduction

Effluent

Reduction

pH

Lead

0.15 mg/L

0.001 mg/L

99.33%

0.001 mg/L

0.010 mg/L

6.5

Lead

0.15 mg/L

0.002 mg/L

98.66%

0.003 mg/L

0.010 mg/L

8.5

Cyst

25000 count/mL

1count/mL

99.99%

3 count/mL

> 99.95%

NA

Turbidity

11.8 NTU

0.12 NTU

98.98%

0.18 NTU

0.5 NTU

NA

Lindane

0.00063 mg/L

0.00005 mg/L

92.06%

0.00005 mg/L

0.00001 mg/L

NA

Atrazine

0.0097 mg/L

0.0002 mg/L

97.93%

0.0006 mg/L

0.003 mg/L

NA

Chlorine

1.9 mg/L

0.09 mg/L

95.26%

0.17 mg/L

75%

NA

Particulate**

286667 count/mL

900 count/mL

99.68%

2400 count/mL

85%

NA

2,4-D

291.6667 ug/L

45.45 ug/L

84.42%

100 ug/L

0.0017 mg/L

NA

Asbestos

458 MFL/mL

0.16 MFL/mL

99.96%

0.16 MFL/mL

99%

NA

Tested using a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa)

ä

under standard laboratory conditions, however, actual performance may vary. Health Claim

Performance tested and certified by NSF International

**Particle size range classification of test. Particles used were 0.5 –1 microns.

22

Page 22
Image 22
Amana XRSS287BW, XRSS287BB manual Water Filter Data, Specifications