installation, start-up and service instructions
588A
Sizes 018-060
589A
SINGLE PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS
Sizes 024-060
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . 1
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
RECEIVING AND INSTALLATION . . . . . . . . . . . . . . . . .
IX. Step 9 Ð Install Duct Connections . . . . . . . . . . . 16 X. Step 10 Ð Install Electrical Connections . . . . . . 18
II. Start Up Heating Section and
Make Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . 23
III. Start Up Cooling Section and
Make Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . 26
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I. Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
II. Unit Top Removal . . . . . . . . . . . . . . . . . . . . . . . . . . 45
III. Evaporator Blower and Motor . . . . . . . . . . . . . . . . 45
IV. Flue Gas Passageways . . . . . . . . . . . . . . . . . . . . . 45
V.
VI. Limit Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
VII. Burner Ignition . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
VIII. Main Burners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
IX. Condenser Coil, Evaporator Coil, and
Condensate Drain Pan . . . . . . . . . . . . . . . . . . . . . . 47
X. Condenser Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
XI. Electrical Controls and Wiring . . . . . . . . . . . . . . . 47
XII. Refrigerant Circuit . . . . . . . . . . . . . . . . . . . . . . . . . 47
XIII. Gas Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
XIV. Evaporator Air¯ow . . . . . . . . . . . . . . . . . . . . . . . . . 47
XV. Metering Device Ð Acutrol™ Device . . . . . . . . . . 47
XVI. Liquid Line Strainer . . . . . . . . . . . . . . . . . . . . . . . . 47
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOTE TO INSTALLER Ð Before the installation, READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY. Also, make sure the User's Manual and Replacement Guide are left with the unit after installation. This unit is NOT to be used for temporary heating of buildings or structures un- der construction.
SAFETY CONSIDERATIONS
Installation and servicing of
Cancels: II | II |
| 9/15/98 |
Fig. 1 Ð Unit 589A Shown With Optional Base Rail
Untrained personnel can perform basic maintenance func- tions of cleaning coils and ®lters. All other operations should be performed by trained service personnel. When working on
Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for unbrazing operations. Have ®re ex- tinguisher available for all brazing operations.
WARNING: Improper installation, adjustment, alter- ation, service, maintenance, or use can cause carbon mon- oxide poisoning, ®re, or an explosion which can result in personal injury or unit damage. Consult a quali®ed installer, service agency, or gas supplier for informa- tion or assistance. The quali®ed installer or agency must use only
WARNING: Before performing service or mainte- nance operations on unit, turn off gas supply then unit main power switch. Electrical shock could cause per- sonal injury.
GENERAL
The 588A, 589A units (see Fig. 1) are fully