REQ'D CLEARANCES FOR SERVICING. in. (mm)

Duct panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 Unit top . . . . . . . . . . . . . . . . . . . . . . . . . 36 (914) Side opposite ducts . . . . . . . . . . . . . . . . . . . . 36 (914) Compressor access . . . . . . . . . . . . . . . . . . . . 36 (914) (Except for NEC requirements)

REQ'D CLEARANCES TO COMBUSTIBLE MAT'L. in. (mm)

Maximum extension of overhangs . . . . . . . . . . . . . 48 (1219)

Unit top . . . . . . . . . . . . . . . . . . . . . . . . . 14 (356)

Duct side of unit . . . . . . . . . . . . . . . . . . . . . . 2 (51)

Side opposite ducts . . . . . . . . . . . . . . . . . . . . 14 (356)

Bottom of unit . . . . . . . . . . . . . . . . . . . . . . . . . 0

Flue panel . . . . . . . . . . . . . . . . . . . . . . . . 36 (914)

NEC REQ'D CLEARANCES. in. (mm)

 

 

 

Between units, control box side

.

. 42

(1067)

Unit and ungrounded surfaces, control box side . . . .

.

. . 36 (914)

Unit and block or concrete walls and other grounded

 

 

 

surfaces, control box side

.

. 42

(1067)

UNIT

ELECTRICAL

UNIT WEIGHT

 

CORNER WEIGHT

 

 

(lb/kg)

 

589A

CHARACTERISTICS

 

 

 

 

lb

kg

A

B

C

D

 

 

024040

208/230-1-60

357

163

110/50

56/25

136/62

55/25

024060

208/230-1-60

369

168

113/51

59/27

139/63

58/26

030040

208/230-1-60

360

164

103/47

72/33

124/56

61/28

030060/080

208/230-1-60

372

169

106/48

75/34

127/58

64/29

036060/080

208/230-1-60, 208/230-3-60, 460-3-60

390

177

100/45

90/41

123/56

77/35

036100/120

208/230-1-60, 208/230-3-60, 460-3-60

402

183

103/47

93/42

127/57

80/36

 

 

 

 

 

 

 

 

UNIT

CENTER OF GRAVITY (in./mm)

589A

X

Y

Z

024040

26.57/674.9

20.17/512.3

14.96/380.0

024060

26.51/673.3

20.22/513.6

14.96/380.0

030040

26.90/683.3

21.09/535.7

14.96/380.0

030060/080

26.83/681.5

21.11/536.2

14.96/380.0

036060/080

26.99/685.5

21.14/537.0

14.96/380.0

036100/120

26.92/683.8

21.14/537.0

14.96/380.0

 

 

LEGEND

 

 

CG

Ð

Center of Gravity

MAT'L

Ð

Material

COND

Ð Condenser

NEC

Ð National Electrical Code

LV

Ð

Low Voltage

REQ'D

Ð

Required

NOTES:

1.Clearances must be maintained to prevent recirculation of air from outdoor- fan discharge.

2.Adequate clearance around air openings into combustion chamber must be provided.

Fig. 7 Ð 589A024-036 With Optional Base Rail, Unit Dimensions

Ð7Ð

Page 7
Image 7
Bryant 588A user manual 589A024-036 With Optional Base Rail, Unit Dimensions, Ð7Ð

589A, 588A specifications

The Bryant 588A is a high-efficiency gas furnace celebrated for its advanced technology and superior performance in residential heating. Known for its reliability and durable construction, this model is ideal for homeowners looking for warmth and comfort during colder months.

One of the standout features of the Bryant 588A is its remarkable AFUE (Annual Fuel Utilization Efficiency) rating, which can reach up to 96.5%. This high efficiency means that a significant portion of the fuel consumed is converted into usable heat, leading to lower energy bills and a reduced carbon footprint. The furnace utilizes a two-stage heating system, which improves comfort levels by providing more consistent temperatures and reducing the frequency of temperature swings in the home.

Another notable characteristic is the incorporation of a multi-speed blower motor. This innovation enhances airflow and optimizes energy use by adjusting the fan speed according to the heating needs of the home. The variable speed operation also helps to minimize noise levels, creating a quieter environment compared to traditional single-speed furnaces.

The Bryant 588A features an advanced control system that allows for better system management and can be integrated with smart home technologies. This allows homeowners to monitor and adjust their heating settings remotely, offering convenience and efficiency. Additionally, the furnace is compatible with Bryant’s Evolution System, which provides advanced diagnostic features and improved energy performance.

Durability is a key characteristic of the Bryant 588A, as it is constructed with a heavy-duty cabinet designed to withstand the rigors of daily use and harsh weather conditions. The unit also includes a corrosion-resistant heat exchanger, ensuring longevity and reliability.

Furthermore, the Bryant 588A operates quietly, thanks to its insulated cabinet and advanced design. This feature is especially appreciated by homeowners seeking a peaceful living environment free from disruptive noises typically associated with heating systems.

In summary, the Bryant 588A gas furnace combines high efficiency, innovative technology, and durable construction. Its effective heating capabilities paired with user-friendly features make it a smart investment for anyone looking to enhance their home heating system while enjoying lower energy costs and increased comfort.