Manuals
/
American Dryer Corp
/
Laundry Appliance
/
Clothes Dryer
American Dryer Corp
AD-24 Phase 7 installation manual American Dryer Corp, 113222
Models:
AD-24 Phase 7
1
18
50
50
Download
50 pages
40.48 Kb
15
16
17
18
19
20
21
22
<
>
Specification
Install
Of Replacement Components
Warranty
Maintenance
2 3-Phase 3ø Wiring Connections/Hookup
System Reset
S.A.F.E. SYSTEM Diagnostics
A. Unpacking/Setting Up
Dual Timer Dryers
Page 18
Image 18
14
American Dryer Corp.
113222 - 5
Page 17
Page 19
Page 18
Image 18
Page 17
Page 19
Contents
AD-24 Installation Manual
Phase
American Dryer Corporation
Retain This Manual in a Safe Place for Future Reference
AD-24 Phase
FOR YOUR SAFETY
POUR VOTRE SÉCURITÉ
FOR YOUR SAFETY
Proposition
The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONALINJURY OR FIRE COULD RESULT
SECTION
SECTION
Table of Contents
SECTION
A. Cleaning
PROCEDURE FOR FUNCTIONAL CHECK
OF REPLACEMENT COMPONENTS
B. Adjustments
EXPLOSION COULD RESULT
SAFETY PRECAUTIONS
SECTION
EXPLOSION COULD RESULT
American Dryer Corp
113222
SPECIFICATIONS
SECTION
Steam
Specifications
American Dryer Corp
113222
SECTION
INSTALLATION PROCEDURES
A. UNPACKING/SETTING UP
B. LOCATION OF THE DRYER
C. DRYER ENCLOSURE REQUIREMENTS
D. FRESH AIR SUPPLY REQUIREMENTS
E. EXHAUST REQUIREMENTS
SINGLE DRYER VENTING
For an 8-inch 20.32 cm horizontal run where a maximum of one 1 elbow is used refer to the illustration below, the ductwork from the dryer outlet must not exceed 40 feet 12.2 meters
SINGLE DRYER VENTING
Page
American Dryer Corp
113222
IMPORTANT VENTING REMINDERS
F. ELECTRICAL INFORMATION
1. Electrical Requirements
a. Gas Models Only
2. Electrical Service Specifications
Electric
b. Electric Models Only
IMPORTANT A separate protected circuit must be provided to each dryer
White or Red + Neutral or L2
Single-Phase Electrical Lead Connections
Black + Positive
Green + Ground
2 3-Phase 3ø Wiring Connections/Hookup
G. GAS INFORMATION
kcal/hr
TYPE OF GAS
TYPE OF GAS
Rating
DO NOT REDUCE THIS PIPE SIZE REQUIREMENT
H. PREPARATION FOR OPERATION/START-UP
I. PREOPERATIONAL TESTS
3.5 inches 8.7 mb water column
J. PREOPERATIONAL INSTRUCTIONS COIN MODELS
DUAL TIMER DRYERS
NON-COIN MODELS
TIMING LEGEND
REVERSING TIMER SPIN/DWELLADJUSTMENTS
K. SHUTDOWN INSTRUCTIONS
a. SHUT OFF external gas supply shutoff valve
SECTION
SERVICE/PARTS INFORMATION
A. SERVICE
B. PARTS
B. WARRANTY
WARRANTY INFORMATION
A. RETURNING WARRANTY CARDS
C. RETURNING WARRANTY PARTS
2. Each part must be tagged with the following information
SUGGESTED CLEANING SCHEDULE
ROUTINE MAINTENANCE
A. CLEANING
SECTION
C. LUBRICATION
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
90 DAYS
American Dryer Corp
DATA LABEL INFORMATION
SECTION
113222
2. SERIAL NUMBER
7. ELECTRIC SERVICE
THE DATA LABEL 1. MODEL NUMBER
3. MANUFACTURING CODE NUMBER
PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS
SECTION
b. Phase 7 Non-Coin Models
2. For Models with Direct Spark Ignition DSI Module Type
SENSOR ACTIVATED FIRE EXTINGUISHING S.A.F.E. SYSTEM
S.A.F.E. System In Action
SECTION
INSTALLATION
BEFORE YOU START CHECK LOCAL CODES AND PERMITS
Typical water supply
2. Water Connections
OPTIONAL MANUAL BYPASS
SYSTEM RESET
S.A.F.E. System Theory of Operation
NON-COIN
S.A.F.E. SYSTEM Diagnostics
S.A.F.E. SYSTEM WATER VALVE CHECK
COIN
S.A.F.E. SYSTEM DIAGNOSTICS MESSAGES
WHEN COMPUTER IS IN “S.A.F.E. SYSTEM IS DISABLED” MODE
STARTING A CYCLE
ADC Part No
5 - 06/03/08