2.Technical Gas Data a. Gas Specifications

 

TYPE OF GAS

 

 

NATURAL

LIQUID PROPANE

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

 

 

 

 

 

Shaded areas are stated in metric equivalents

*Measured at outlet side of gas valve pressure tap when gas valve is on.

b.Gas Connections:

Inlet connection ---- 1/2” N.P.T.

Inlet supply size ---- 1/2” Pipe (minimum) Btu/hr input --------- 60,000 (15,120 kcal/hr)

1)Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

 

 

 

TYPE OF GAS

 

Liquid Propane

 

kcal/hr

 

Natural

 

 

Liquid Propane

Btu/hr

 

 

 

Conversion Kit

 

 

 

Part

 

 

 

Part

Rating

Rating

Qty.

D.M.S.*

 

Qty.

D.M.S.*

 

Part Number

 

 

 

 

 

Number

 

 

 

Number

 

60,000

15,120

2

#37

 

140815

2

#52

 

140800

874058

 

 

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas

#37

=

0.1040” (2.6416 mm).

Liquid Propane Gas

#52

=

0.0635” (1.6129 mm).

22

American Dryer Corp.

113222 - 5

Page 26
Image 26
American Dryer Corp AD-24 Phase 7 installation manual Type of GAS