REVERSING TIMER SPIN/DWELLADJUSTMENTS

REVERSING TIMER SPIN/DWELLADJUSTMENTS

Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear area of the dryer.

Both the Dwell (stop) Time and the basket (tumbler) Spin Time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

 

 

 

SPIN TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment Position Number

1

2

 

3

4

5

 

 

 

 

 

 

 

Time in Seconds*

30

60

 

90

120

150

 

 

 

 

 

 

 

DWELL (STOP) TIME

 

 

 

 

 

 

Adjustment Position Number

1

2

 

3

4

5

 

 

 

 

 

 

 

Time in Seconds*

5

6.3

 

7.6

8.9

10.2

 

 

 

 

 

 

 

* Values shown are +/- 1-second.

 

 

 

 

 

 

 

 

 

 

 

 

K. SHUTDOWN INSTRUCTIONS

If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:

1.Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2.Discontinue the gas supply (for gas models only):

a.SHUT OFF external gas supply shutoff valve.

b.SHUT OFF internal gas supply shutoff valve located in the gas valve burner area.