American Dryer Corp AD-24 Phase 7 Electrical Service Specifications, a. Gas Models Only

Models: AD-24 Phase 7

1 50
Download 50 pages 40.48 Kb
Page 21
Image 21
2.Electrical Service Specifications

2.Electrical Service Specifications

IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the factory.

a. Gas Models Only

Gas

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

 

SERVICE

PHASE

WIRE

APPROX.

CIRCUIT

 

AMP DRAW

 

VOLTAGE

SERVICE

BREAKER

 

 

 

 

60 Hz

50 Hz

 

 

120

2

8.7

15

 

208

2

5.2

15

 

240

2

4.8

5.8

15

 

208

3

3.0

15

 

240

3

3.2

3.6

15

 

380-400

4*

2.2

15

 

416

4*

2.3

15

 

460/480

3

2.1

15

* 3-Wire is available.

 

 

 

6/3/08

b.Electric Models Only

ALL electrically heated dryers must be connected to the electric service shown on the dryer’s data label. The connecting wires must be properly sized to handle the rated current.

Electric

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

60 Hz

50 Hz

CIRCUIT

BREAKER

 

 

18 kW

 

 

 

 

208

2

 

92

125

 

240

2

 

81

110

 

240

2

 

80

100

 

208

3

 

55

70

 

240

3

 

48

60

 

 

 

20 kW

 

 

 

 

208

2

 

101

150

 

240

2

 

88

110

 

 

 

24 kW

 

 

 

 

208

3

 

72

90

 

240

3

 

63

80

 

416

4*

 

39

50

 

460

3

 

32

40

 

480

3

 

31

40

 

* 3-Wire is available.

 

 

 

 

6/3/08

113222 - 5

www.amdry.com

17

Page 21
Image 21
American Dryer Corp AD-24 Phase 7 Electrical Service Specifications, a. Gas Models Only, b. Electric Models Only