SPECIFICATIONS

MAXIMUM CAPACITY (DRY WEIGHT)

 

20 lb

 

9.07 kg

TUMBLER DIAMETER

 

27-1/4”

 

69.22 cm

TUMBLER DEPTH

 

 

 

24”

 

60.96 cm

TUMBLER VOLUME

 

 

 

8.10 cu ft

229.37 L

TUMBLER/DRIVE MOTOR

 

1/2 hp

 

0.37 kW

BLOWER/FAN MOTOR

 

 

N / A

 

DOOR OPENING (DIAMETER)

 

21-1/2”

 

54.61 cm

DOOR SILL HEIGHT

 

 

 

28-1/3”

 

71.91 cm

WATER CONNECTION*

 

 

3/4” F.N.P.T.

 

DRYERS PER 20’/40’ CONTAINER

 

 

14 / 30

 

DRYERS PER 48’/53’ TRUCK

 

 

42 / 47

 

 

VOLTAGE AVAILABLE

 

120-480V

1,3ø

2,3,4w

50/60 Hz

 

APPROXIMATE NET WEIGHT

 

426 lb

 

193.23 kg

 

APPROXIMATE SHIPPING WEIGHT

461 lb

 

209.11 kg

Gas

AIRFLOW

 

 

60 Hz

400 cfm

 

11.33 cmm

 

 

 

 

50 Hz

333 cfm

9.44 cmm

 

 

 

 

 

 

HEAT INPUT

 

 

 

60,000 Btu/hr

15,120 kcal/hr

 

EXHAUST CONNECTION (DIAMETER)

6”

 

15.24 cm

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

INLET PIPE CONNECTION

 

 

1/2” M.N.P.T.

 

 

VOLTAGE AVAILABLE

 

208-480V

1,3ø

2,3,4w

50/60 Hz

 

APPROXIMATE NET WEIGHT

 

426 lb

 

193.23 kg

 

APPROXIMATE SHIPPING WEIGHT

461 lb

 

209.11 kg

Electric

AIRFLOW

 

 

60 Hz

400 cfm

 

11.33 cmm

 

 

OVEN SIZE

50 Hz

333 cfm

9.44 cmm

 

 

 

 

 

 

EXHAUST CONNECTION (DIAMETER)

6”

 

15.24 cm

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

 

 

 

 

 

 

 

 

 

kW

 

Btu/hr

 

kcal/hr

 

 

 

 

 

18

 

61,400

 

15,500

 

 

 

 

 

20

 

68,200

 

17,200

 

 

 

 

 

24

 

81,900

 

20,600

 

 

 

 

 

VOLTAGE AVAILABLE

 

 

 

 

 

 

APPROXIMATE NET WEIGHT

 

 

 

 

 

 

APPROXIMATE SHIPPING WEIGHT

 

 

 

 

Steam

AIRFLOW

 

 

60 Hz

 

 

 

 

 

 

 

 

50 Hz

 

 

 

 

STEAM CONSUMPTION

 

 

 

 

 

 

 

 

 

 

 

 

OPERATING STEAM PRESSURE

 

N / A

 

 

EXHAUST CONNECTION (DIAMETER)

 

 

 

 

 

COMPRESSED AIR CONNECTION

 

 

 

 

 

COMPRESSED AIR VOLUME

 

 

 

 

 

 

BOILER HORSEPOWER (NORMAL LOAD)

 

 

 

 

 

SUPPLY CONNECTION

 

 

 

 

 

 

RETURN CONNECTION

 

 

 

 

 

Shaded areas are stated in metric equivalents

 

 

 

10/04/06

* Water supply must be 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) for fire suppression system to operate properly.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.