SECTION II
SPECIFICATIONS
MAXIMUM CAPACITY (DRY WEIGHT) |
| 20 lb |
| 9.07 kg | |||||
TUMBLER DIAMETER |
|
| 69.22 cm | ||||||
TUMBLER DEPTH |
|
|
| 24” |
| 60.96 cm | |||
TUMBLER VOLUME |
|
|
| 8.10 cu ft | 229.37 L | ||||
TUMBLER/DRIVE MOTOR |
| 1/2 hp |
| 0.37 kW | |||||
BLOWER/FAN MOTOR |
|
| N / A |
| |||||
DOOR OPENING (DIAMETER) |
|
| 54.61 cm | ||||||
DOOR SILL HEIGHT |
|
|
|
| 71.91 cm | ||||
WATER CONNECTION* |
|
| 3/4” F.N.P.T. |
| |||||
DRYERS PER 20’/40’ CONTAINER |
|
| 14 / 30 |
| |||||
DRYERS PER 48’/53’ TRUCK |
|
| 42 / 47 |
| |||||
| VOLTAGE AVAILABLE |
| 1,3ø | 2,3,4w | 50/60 Hz | ||||
| APPROXIMATE NET WEIGHT |
| 426 lb |
| 193.23 kg | ||||
| APPROXIMATE SHIPPING WEIGHT | 461 lb |
| 209.11 kg | |||||
Gas | AIRFLOW |
|
| 60 Hz | 400 cfm |
| 11.33 cmm | ||
|
|
|
| 50 Hz | 333 cfm | 9.44 cmm | |||
|
|
|
|
| |||||
| HEAT INPUT |
|
|
| 60,000 Btu/hr | 15,120 kcal/hr | |||
| EXHAUST CONNECTION (DIAMETER) | 6” |
| 15.24 cm | |||||
| COMPRESSED AIR CONNECTION |
| N / A |
| |||||
| COMPRESSED AIR VOLUME |
|
| N / A |
| ||||
| INLET PIPE CONNECTION |
|
| 1/2” M.N.P.T. |
| ||||
| VOLTAGE AVAILABLE |
| 1,3ø | 2,3,4w | 50/60 Hz | ||||
| APPROXIMATE NET WEIGHT |
| 426 lb |
| 193.23 kg | ||||
| APPROXIMATE SHIPPING WEIGHT | 461 lb |
| 209.11 kg | |||||
Electric | AIRFLOW |
|
| 60 Hz | 400 cfm |
| 11.33 cmm | ||
|
| OVEN SIZE | 50 Hz | 333 cfm | 9.44 cmm | ||||
|
|
|
|
| |||||
| EXHAUST CONNECTION (DIAMETER) | 6” |
| 15.24 cm | |||||
| COMPRESSED AIR CONNECTION |
| N / A |
| |||||
| COMPRESSED AIR VOLUME |
|
| N / A |
| ||||
|
|
|
|
|
|
|
|
|
|
| kW |
| Btu/hr |
| kcal/hr |
|
|
|
|
| 18 |
| 61,400 |
| 15,500 |
|
|
|
|
| 20 |
| 68,200 |
| 17,200 |
|
|
|
|
| 24 |
| 81,900 |
| 20,600 |
|
|
|
|
| VOLTAGE AVAILABLE |
|
|
|
|
| |||
| APPROXIMATE NET WEIGHT |
|
|
|
|
| |||
| APPROXIMATE SHIPPING WEIGHT |
|
|
|
| ||||
Steam | AIRFLOW |
|
| 60 Hz |
|
|
|
| |
|
|
|
| 50 Hz |
|
|
|
| |
STEAM CONSUMPTION |
|
|
|
|
| ||||
|
|
|
|
|
| ||||
| OPERATING STEAM PRESSURE |
| N / A |
| |||||
| EXHAUST CONNECTION (DIAMETER) |
|
|
|
| ||||
| COMPRESSED AIR CONNECTION |
|
|
|
| ||||
| COMPRESSED AIR VOLUME |
|
|
|
|
| |||
| BOILER HORSEPOWER (NORMAL LOAD) |
|
|
|
| ||||
| SUPPLY CONNECTION |
|
|
|
|
| |||
| RETURN CONNECTION |
|
|
|
|
| |||
Shaded areas are stated in metric equivalents |
|
|
| 10/04/06 |
* Water supply must be 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) for fire suppression system to operate properly.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.
113222 - 5 | www.amdry.com | 5 |