310 (Steam) Non-Tilt

25 HP Blower Motor/5 HP Drive Motor

IMPORTANT: 208 VAC and 230 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A.

B.

C.

Fuse ratings are dual element, time delay, current limiting, class RK1 or RK5 ONLY. Circuit breakers are thermal/magnetic (industrial) motor curve type ONLY. For others, calculate/ verify correct breaker size according to appliance amp draw rating and type of breaker used.

Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

FUSING

CIRCUIT

Dual Element

VOLTAGE

SERVICE

AMP DRAW

BREAKER

 

Time Delay

 

 

 

 

 

208

3/4

81

100

110

 

 

 

 

 

 

230

3

72

100

110

 

 

 

 

 

 

380

3/4

45

60

90

416

3/4

40

60

80

 

 

 

 

 

 

460/480

3/4

40

60

80

 

 

 

 

 

 

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the right electrical control panel.

WARNING: 208 VAC and 230 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.

NOTE: ADC reserves the right to make any changes in specifications at any time without notice or obligation.