J. PREOPERATIONAL TESTS

ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be preformed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.

1.Turn on electric power to the dryer.

2.Make sure the loading doors are closed and the lint drawer is closed.

3.Make sure “green” power button is in and illuminated.

4.Microprocessor controller (computer) system operational test -- to start the dryer:

a.Display will read “READY.”

b.Press “D” (preprogrammed) cycle key on the keyboard (touch pad).

5.The dryer will then start. (i.e., blower, basket [tumbler] and heat)

6.The light emitting diode (L.E.D.) display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.

NOTE: Press the “UP ARROW” to view the basket (tumbler) temperature at anytime.

NOTE: The dryer can be stopped at anytime by pressing the “STOP/CLEAR”

 

key. If the

temperature is above the Cool Down set point when the “STOP/CLEAR” is pressed, the dryer will go into a Cool Down Cycle. If the “STOP/CLEAR” key is pressed again at this point the cycle that was in progress will be canceled and returned to the “READY” state. If the temperature is below the Cool Down set point. The cycle that was in progress will be canceled, and go to Wrinkle Guard.

7.When the programmed drying time has expired, the Phase 7 OPL microprocessor controller (computer) will proceed into the Cool Down Cycle (Mode).

8.Once the Cool Down Cycle begins at the end of the heat cycle the L.E.D. display will read COOL DOWN TEMP ___/___MINUTE REMAINING. At the end of the heat cycle the dryer will shut off the heat, and continue the fan and basket (tumbler) until the Cool Down Time, or temperature is reached.

9.Once the Cool Down Cycle is completed the Phase 7 OPL microprocessor controller (computer) will proceed into the Wrinkle Guard Cycle. The Audio Alert tone will sound for (the amount set in Audio Alert ON Time). The L.E.D. display will read “WRINKLE GUARD.” The times are fixed at two (2) minutes OFF, 2 minutes ON for a max time of 99 minutes. These times are not programmable. During the ON time, the Blower (fan) and the (basket) tumbler will start to rotate (without heat for two [2] minutes). The Phase 7 OPL microprocessor controller (computer) will repeat this process until the Maximum Wrinkle Guard On Time has expired (99 minutes). The L.E.D. display will then read “CYCLE DONE” and lockout the dryer functions until the doors are opened. It will then return to “READY.”

NOTE: Mechanical functions of the dryer is not allowed during the ON time. The blower (fan) must be OFF to perform mechanical functions. However the “STOP/CLEAR” key may be pressed at any time to end a the Wrinkle Guard cycle. Mechanical functions of the dryer is allowed during the OFF time.

38

Page 42
Image 42
American Dryer Corp AD-310 Phase 7 installation manual Preoperational Tests