INPUTS: (RED) | OUTPUTS: (GREEN) | ||
1. | FDRC - Front Door Closed | 1. | R_HEAT - Rear Heat |
2. | FDRO - Front Door Open | 2. | AUDIO ALERT - Horn On |
3. | TBOL - Basket (Tumbler) Overload | 3. | FWD - Basket (Tumbler) Forward |
4. | FNOL - Fan Overload | 4. | REV - Basket (Tumbler) Reverse |
5. | RDWN - Rear Down | 5. | AIR JET - Air Jet On |
6. | FDWN - Front Down | 6. | FAN - Blower Fan On |
7. | RDRC - Rear Door Closed | 7. | F_HEAT - Front Heat |
8. | RDRO - Rear Door Open | 8. | PRG1 - Programmable Output #1 |
9. | FAN - Blower Fan On | 9. | PRG2 - Programmable Output #2 |
10. | RBHL - Rear Burner High Limit | 10. | PRG3 - Programmable Output #3 |
11 | R_SS - Rear Sail Switch | 11. | PRG4 - Programmable Output #4 |
12. | FBHL - Front Burner High Limit | 12. | OCL1 - Open Collector Output #1 |
13. | F_SS - Front Sail Switch | 13. | OCL2 - Open Collector Output #2 |
14. | EXHL - Exhaust High Limit | 14. | OCL3 - Open Collector Output #3 |
15. | DRY - Dry Enable Bit | 15. | OCL4 - Open Collector Output #4 |
16. | LINT - Lint Drawer | 16. | OCL5 - Open Collector Output #5 |
17. | R_HE - Rear Heat Enable | 17. | OCL6 - Open Collector Output #6 |
18. | F_HE - Front Heat Enable | 18. | OCL7 - Open Collector Output #7 |
19. | 24VIN - Control Voltage 24 Volts AC | 19. | OCL8 - Open Collector Output #8 |
20. | SPR5 - Spare Input #5 | 20. | EOC - End Of Cycle Light |
21.SPR4 - Spare Input #4
22.SPR3 - Spare Input #3
23.SPR2 - Spare Input #2
24.SPR1 - Spare Input #1
25.RVLV - Rear Gas Valve
26.FVLV - Front Gas Valve
27.24IN - Board 24 Volt AC
28.+5V - Regulated Voltage
29.Model - Communication
Input/Output (I/O) Board Input Description (“Red” light emitting diode [L.E.D.])
1. | FDRC – (RED L.E.D.) | This L.E.D. will indicate the status of the Front Doors. If the doors are closed, |
|
| then the L.E.D. is ON. |
2. | FDRO – (RED L.E.D.) | This L.E.D. will indicate the status of the Front Doors. If the doors are open, |
|
| then the L.E.D. is ON. |
3. | TBOL – (RED L.E.D.) | This L.E.D. will indicate the status of the Basket (tumbler) Overload Contact. |
|
| If the contact is closed, then the L.E.D. is ON. If it faults open, then the L.E.D. |
|
| is OFF. |
4. | FNOL – (RED L.E.D.) | This L.E.D. will indicate the status of the Fan Overload Contact. If the contact |
|
| is closed, then the L.E.D. is ON. If it faults open, then the L.E.D. is OFF. |
5. | RDWN – (RED L.E.D.) | This L.E.D. will indicate the status of the Rear Tilt. If the rear of the dryer is |
|
| down, then the L.E.D. is ON (optional). |
6. | FDWN – (RED L.E.D.) | This L.E.D. will indicate the status of the Front Tilt. If the front of the dryer is |
|
| down, then the L.E.D. is ON (optional). |
7. | RDRC – (RED L.E.D.) | This L.E.D. will indicate the status of the Rear Doors. If the doors are closed, |
|
| then the L.E.D. is ON. |