Sprinkler Option Temperature Controller Settings

NOTE: Refer to Controller’s User’s Manual for further information on controller options.

Message

Message

Settings

Display

Description

 

 

 

 

SECr

SECURITY CODE

FULL SECURITY - SET TO 110 (DISPLAYED AS 1) "VIEW ONLY"

NO SECURITY - SET TO 111 (DISPLAYED AS 4)

 

 

"ALL FEATURES UNLOCKED"

 

 

 

InP

INPUT DEVICE

P 385 = RTD INPUT

 

 

 

F-C

º F OR º C

SELECT TYPE REQUIRED (FAHRENHEIT OR CELSIUS)

 

 

 

dPt

DECIMAL POINT

0, NO DECIMAL POINT

 

 

 

InPt

INPUT FAULT TIMER

0.2

 

 

 

SPL

SET POINT LOW

500 (SETTING CANNOT BE LOWER)

 

 

 

SPH

SET POINT HIGH

700 (SETTING CANNOT BE HIGHER)

 

 

 

SPSt

SET POINT STATE

rE (REVERSE ACTION)

 

 

 

SPLP

SET POINT LAMP

0 oFF (LAMP OFF WHEN OUTPUT IS ON)

 

 

 

AL

HIGH ALARM ONLY

Hi

 

 

 

ALt

ALARM TYPE

Abs (ABSOLUTE ALARM)

 

 

 

ALrE

ALARM RESET

OnOF (AUTOMATIC RESET)

 

 

 

ALPi

ALARM POWER

OFF (ALARM INHIBIT IS OFF)

INTERRUPT

 

 

 

 

 

ALiH

ALARM INHIBIT

OFF (ALARM INHIBIT IS OFF)

 

 

 

ALSt

ALARM OUTPUT

CLOS

STATE

(CLOSES CONTACTS AT ALARM SET POINT)

 

 

 

 

ALLP

ALARM LAMP

0 ON (ALARM LAMP IS ON WHEN ALARM CONTACT IS CLOSED)

 

 

 

ALHi

ALARM HI

575º F OR 301.6º C (NOTE: ADJUST SAME AS SP)

 

 

 

Cy

CYCLE RATE

OnOF

 

 

 

SP_d

SET POINT ON-OFF

-1

DIFFERENTIAL

 

 

 

 

 

rt

RAMP TIME

OFF

 

 

 

InPC

INPUT CORRECTION

0

 

 

 

FiLt

DIGITAL FILTER

2

 

 

 

SP

TEMPERATURE

575º F OR 301.6º C

SET POINT

 

 

 

 

 

Note: When message display (Cy) set to OnOF.

SPOL (SET POINT OUTPUT LOW LIMIT) not in use.

SPOH (SET POINT OUTPUT HIGH LIMIT) not in use.

Are not displayed.

75

Page 79
Image 79
American Dryer Corp AD-310 Phase 7 installation manual Sprinkler Option Temperature Controller Settings