Input/Output (I/O) Board Output Description (“Green” light emitting diode [L.E.D.])
1. | R_HEAT – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Rear Heat output. If the request |
|
| to turn on the Rear Burner is made, then the L.E.D. is ON. |
2. | ALERT – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Horn output. If the request to |
|
| turn on the Horn is made, then the L.E.D. is ON. |
3. | FWD – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Basket (tumbler) Forward direction |
|
| output. If the request to tumble the drum in the Forward direction is made, |
|
| then the L.E.D. is ON. |
4. | REV – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Basket (tumbler) Reverse direction |
|
| output. If the request to tumble the drum in the Reverse direction is made, |
|
| then the L.E.D. is ON. |
5. | AIR JET – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Air Jet output. If the request to |
|
| turn on the Air Jet is made, then the L.E.D. is ON. |
6. | FAN – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Fan output. If the request to turn |
|
| on the Fan (blower) is made, then the L.E.D. is ON. |
7. | F_HEAT – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Front Heat output. If the request |
|
| to turn on the Front Burner is made, then the L.E.D. is ON. |
8. | PGR1 – (GREEN L.E.D.) | This is for a spare output to be programmed. |
9. | PGR2 – (GREEN L.E.D.) | This is for a spare output to be programmed. |
10. | PGR3 – (GREEN L.E.D.) | This is for a spare output to be programmed. |
11. | PGR4 – (GREEN L.E.D.) | This is for a spare output to be programmed. |
12. | OCL1 – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Open Collector #1 output. If the |
|
| request to turn on the Open Collector #1 is made, then the L.E.D. is ON. |
|
| (Programmable and Defaulted to Front Door Open.) |
13. | OCL2 – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Open Collector #2 output. If the |
|
| request to turn on the Open Collector #2 is made, then the L.E.D. is ON. |
|
| (Programmable and Defaulted to Front Door Closed.) |
14. | OCL3 – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Open Collector #3 output. If the |
|
| request to turn on the Open Collector #3 is made, then the L.E.D. is ON. |
|
| (Programmable and Defaulted to Lint Drawer.) |
15. | OCL4 – (GREEN L.E.D.) | This L.E.D. will indicate the status of the Open Collector #4 output. If the |
|
| request to turn on the Open Collector #4 is made, then the L.E.D. is ON. |
|
| (Programmable and Defaulted to Front Down.) |
63