e.The Manual Reset Basket (tumbler)
f.The gas valve used in the dryer is of the redundant type which means that the gas valve is actually two (2) gas valves in one (1); one (1) in series with the other. This is a safety feature which provides protection against gas flow in the event that one
(1) of the valves does not seat properly. The valve also regulates the incoming gas pressure.
NOTE: THE DSI GAS VALVES ARE NOT FIELD REPAIRABLE.
225º F (107º C) Thermostat
Redundant Gas Valve
g.Normal Operation of the Direct Spark Ignition (DSI) System (refer to the illustration on page 17).
1)The DSI System consists of a
On a call for heat by the dryer’s controls, 24 VAC is applied to the DSI module at which time the module’s light emitting diode (L.E.D.) indicator will light “red” indicating that power has been established to the module. Almost immediately (up to approximately
If at this time the flame has not been established and confirmed, the DSI module will “LOCKOUT” and the module’s L.E.D. indicator will light “red” and stay on continuously. “Burner Ignition Control Fault” will display. To clear this fault press the “CLEAR/STOP” key.
Once the burner flame is established and confirmed, the DSI module indicator will light “green,” and the burner system will continue through a normal heating cycle, where the DSI system will cycle on and off as required by the dryer’s controls.
During the normal heating cycle, should a “FLAMEOUT” occur (i.e., severe air turbulence forces the flame away from the
1 9