American Dryer Corp AD-310 Phase 7 service manual

Models: AD-310 Phase 7

1 116
Download 116 pages 19.79 Kb
Page 76
Image 76

d.Proximity Switch Replacement

1)Discontinue electrical power to the dryer.

2)Remove the two (2) 1/4-20 x 1/2” bolts from each side of the middle guard and then remove the guard.

3)Remove the three (3) 1/4-20 x 3/4” bolts from the bottom guard.

Take notice of the depth of the proximity switch.

4)Unscrew and remove the nut that is on the bottom of the proximity switch.

5)Install new proximity switch.

6)Set gap between the proximity switch and the magnet at 3/16” +/- 1/32” (4.7625 mm +/- 0.79248 mm).

7)Reinstall middle guard and secure with the bolts removed in Step #2.

8)Reestablish electrical power to the dryer.

e.Right Load Door Glass (window) Replacement

1)Remove ALL of the old silicone from around the door glass.

2)Clean glass door opening (with alcohol) to remove ALL foreign residue.

3)Carefully clean new door glass with alcohol prior to installation.

4)Apply a bead of silicone (ADC Part No. 170730) to the outer perimeter of the door glass opening.

Carefully insert new door glass within door glass opening.

5)Allow a full 72 hours for the silicone to cure.

6)Trim excess silicone (with razor blade) after cure time.