Input/Output (I/O) Board Input Description (Red light emitting diode [L.E.D.])

1.

FDRC – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Doors. If the doors are closed,

 

 

then the L.E.D. is ON.

2.

FDRO – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Doors. If the doors are open,

 

 

then the L.E.D. is ON.

3.

TBOL – (RED L.E.D.)

This L.E.D. will indicate the status of the Basket (Tumbler) Overload Contact.

 

 

If the contact is closed, then the L.E.D. is ON. If it faults open, then the L.E.D.

 

 

is OFF.

4.

FNOL – (RED L.E.D.)

This L.E.D. will indicate the status of the Fan Overload Contact. If the contact

 

 

is closed, then the L.E.D. is ON. If it faults open, then the L.E.D. is OFF.

5.

RDWN – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Tilt. If the rear of the dryer is

 

 

down, then the L.E.D. is ON.

6.

FDWN – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Tilt. If the front of the dryer is

 

 

down, then the L.E.D. is ON.

7.

RDRC – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Doors. If the doors are closed,

 

 

then the L.E.D. is ON.

8.

RDRO – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Doors. If the doors are open,

 

 

then the L.E.D. is ON.

9.

FAN – (RED L.E.D.)

This L.E.D. will indicate the status of the Blower Fan. If the fan is on, then the

 

 

L.E.D. is ON.

10.

RBHL – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Burner Hi-Limit Disk. If the

 

 

disk is closed (Temperature below 225º F [107º C]), then the L.E.D. is ON.

11.

R_SS – (RED L.E.D.)

This L.E.D. will indicate the status of the Rear Sail Switch. If the switch is

 

 

closed, then the L.E.D. is ON.

12.

FBHL – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Burner Hi-Limit Disk. If the

 

 

disk is closed (Temperature below 225º F [107º C]), then the L.E.D. is ON.

13.

F_SS – (RED L.E.D.)

This L.E.D. will indicate the status of the Front Sail Switch. If the switch is

 

 

closed, then the L.E.D. is ON.

14.

EXHL – (RED L.E.D.)

This L.E.D. will indicate the status of the Exhaust Hi-Limit Disk. If the disk is

 

 

closed (Temperature below 225º F [107º C]), then the L.E.D. is ON.

15.

DRY – (RED L.E.D.)

This L.E.D. will indicate the status of the Programmable Logic Controller (PLC).

 

 

If the mechanical functions of the dryer have been set to the DRY position, the

 

 

PLC will send a signal to the Phase 7 board. This signal will indicate that ALL

the doors are closed and the dryer is level. When these conditions are met, then the L.E.D. is ON.

9 8

Page 102
Image 102