C. DRYER ENCLOSURE REQUIREMENTS

Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of twelve (12) inches (30.48 cm) above the dryer's outer top; eighteen (18) inches (45.72 cm) for steam dryers, except along the front of the dryer which may be closed if desired.

NOTE: Allowances must be made for opening the control door.

X = 12" (30.48 cm) minimum, 24" (60.96 cm) suggested for ease of maintenance.

*1" (2.54 cm) maximum for electric dryers.

**18" (45.72 cm) minimum for steam dryers.

NOTE: Air considerations are important for proper and efficient operation.

Dryers may be positioned side wall to side wall. However, a 1/16" (0.16 cm) minimum allowance must be made for opening and closing of the control door. It is suggested that the dryer be positioned about two (2) feet (0.61 meters)away from the nearest obstruction for ease of installation, maintenance, and service (to be measured from the back guard). Refer to the illustration above for details.

10