SECTION IX

REVERSING TIMER SPIN/DWELL

ADJUSTMENTS

Dual timer models with "reversing option" have an electric reversing timer in the electric service box which is located in the upper rear area of the dryer.

Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

SPIN TIME

Switch Position Number

1

2

3

4

5

 

 

 

 

 

 

Time in Seconds*

30

60

90

120

150

 

 

 

 

 

 

 

 

 

 

 

 

DWELL (STOP) TIME

1

2

3

4

5

 

 

 

 

 

 

Switch Position Number

5

6

8

10

12

 

 

 

 

 

 

* Values shown are +/- 1 second.