American Dryer Corp ML-310 Phase 7 service manual First Visual Check

Models: ML-310 Phase 7

1 116
Download 116 pages 27.96 Kb
Page 24
Image 24

h. Troubleshooting Flowchart - Quick Reference...

First Visual Check

No Spark And System Does Not Work

Is power available

to primary?

No

Yes

 

 

 

Determine why voltage is not present.

Is 24 VAC available at transformer?

No

Yes

Replace

Transformer.

Reset

or replace hi-limits

Is 24 VAC present from terminal

THS(2) to ground?

No

Yes

Are thermostat contacts and hi-limit control contacts closed?

No

Yes

Check continuity of wiring to determine why voltage does not exist at THS(2).

Is jumper installed from terminal 5 to ground?

Install

 

 

 

 

 

 

No

Yes

Jumper.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open thermostat contacts for 30 seconds. Close contacts and wait for prepurge (if applicable)

period. Is spark present now?

No

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn off supply voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check high voltage cable.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is it securely attached

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to DSI module?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is condition of high voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable good (not brittle,

 

 

 

 

 

No

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

burnt, or cracked)?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Securely attach wire

 

 

 

 

 

 

 

 

No

 

Yes

 

 

 

 

to DSI module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace high

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is spark electrode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ceramic cracked

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or is electrode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

grounded out?

 

 

 

 

 

 

 

 

 

Replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

Yes

 

 

 

 

 

 

 

 

 

DSI module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace spark electrode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

assembly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System was in lockout.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Observe a complete operating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cycle to determine why

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

control locked out.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 0

Page 24
Image 24
American Dryer Corp ML-310 Phase 7 service manual First Visual Check