a)Thermal Magnetic Starter (TMS) Replacement

(1)Discontinue electrical power to the dryer.

(2)Mark L1, L2, L3, and T1, T2, T3 on the wires to the TMS for correct replacement.

(3)Set the amp rating on the TMS according to the manufacturer’s electrical schematic on the new thermal magnetic starter.

(4)To remove the thermal magnetic starter, pull the tab on the bottom and lift upward.

(5)To install new thermal magnetic starter, reverse above procedure (Step #4 thru Step #2).

(6)Reestablish electrical power to the dryer.