c)Dryer level switches circuit branch...
(1)On
(2)On
d)Lint drawer closed circuit branch...
The lint drawer closed switch is located in the front of the dryer. When the lint drawer is closed, it closes the switch contacts, powering the lint drawer closed relay. Then, the dry enable relay will close, supplying 24 VAC to the TSX 07 PLC. When the lint drawer is closed, the lint drawer light emitting diode (L.E.D.) is on.
b.Phase 7 Microprocessor Controller (computer)
1)The temperature sensor probe is a bullet shaped device that is located above the lint basket. This temperature probe is used to sense the temperature in the exhaust of the dryer. The temperature sensor is a two (2) terminal monolithic integrated circuit temperature transducer that provides an
output current proportional to absolute temperature. The transducer acts as a high impedance temperature dependent current source of 1∝ A/ºK. The typical accuracy of this probe is +/- 1.5º C (+/- 2.7º F). In a case where the temperature reaches 220º F (104º C), the Phase 7 microprocessor controller (computer) will shut down and the L.E.D. will display “Exhaust High Temp Fault.” To restart a cycle the “CLEAR/STOP” button must first be pressed.
ºF | = | 9 | (ºC + 32) |
|
|
5 | ºC + ºK (273.15) |
| |||
|
|
| TEMPERATURE SENSOR CURRENT = | = MICROAMPS (µA) | |
|
| 5 | 1,000,000 | ||
ºC | = | (ºF - 32) |
| ||
|
| ||||
9 |
|
|
To check a temp sensor you first need a Digital Multimeter (DMM) with a diode check position. Put the meter on diode check, place the red lead of the meter on the black lead of the temp sensor and the black lead of the meter on the white temperature sensor wire. At this point you should get no response from meter (infinite). If you get a reading the temp sensor is defective.