American Dryer Corp ML-310 Phase 7 service manual Door Systems

Models: ML-310 Phase 7

1 116
Download 116 pages 27.96 Kb
Page 72
Image 72

J. DOOR SYSTEMS

The dryer utilizes two (2) styles of doors, which are Manual Doors and Pneumatic Automatic Doors.

1.Manual Door Description

The Manual Doors run on a single aluminum track with a wheel assembly mounted above the doors and a channel with teflon strips mounted on the bottom of the doors...

a.For dryers manufactured as of October 19, 1999, there are trolley bolts located at the top of the doors to secure the doors onto the track.

In the center portion on the top of the doors there is a magnet used in conjunction with proximity sensors which are mounted above the doors.

2.Pneumatic Automatic Door Description/Operation

a.Description

The Pneumatic Automatic Doors run on a single aluminum track mounted above the doors and a split track mounted on the bottom of the doors. The doors are held on the track by four (4) stainless steel wheel assemblies; two (2) are located on the top of the doors and two (2) are located on the bottom of the doors. Additionally, in the center portion on the top of the doors there is a magnet used in conjunction with proximity sensors which are mounted above the doors.

b.Operation

There are two (2) 1-inch (2.54 cm) bore x 18-3/8” (46.67 cm) stroke cable cylinders attached to the top of the doors to pneumatically open and close the doors. When air is applied into the outside ports of these cable cylinders the doors will open. If air is applied into the inside ports of these cable cylinders the doors will close. On each of the four (4) ports is a flow control valve used for adjusting the opening and closing speeds of the doors. These flow controls only vary the speed in the exhaust direction. Air to the cable cylinders is supplied through a 4-way valve. When 24 VAC is applied to the valve, the doors open...if no power is applied, the doors close. A 3-way valve is used to supply air to the 4-way valve.

If the “EMERGENCY STOP” (E-Stop) is engaged, the air is automatically exhausted so that the doors can be opened manually.

1)In a 2 door application, there are two (2) additional cable cylinders and a 4-way valve added for the operation of the rear doors.

6 8

Page 72
Image 72
American Dryer Corp ML-310 Phase 7 service manual Door Systems