TYPE OF GAS

 

Btu/hr

kcal/hr

 

Natural

 

 

Liquid Propane

 

 

 

 

 

 

 

Rating

Rating

Qty.

D.M.S.*

 

Part No.

Qty.

D.M.S.*

Part No.

 

 

 

160,000

40,320

3

#29

 

140820

3

#48

140804

 

Liquid Propane Conversion Kit Part Number 881598

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent

 

 

 

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas

#29

=

0.1360” (3.4544 mm).

Liquid Propane Gas ..

#48

=

0.0760” (1.9304 mm).

Piping/Connections

All components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA- B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of all the appliance Btus being supplied.

The dryer is provided with a 3/4” N.P.T. inlet pipe connection located at the rear upper left side of the dryer. The minimum pipe size (supply line) to the dryer is 3/4” diameter. For ease in servicing, the gas supply line of each dryer must have its own shutoff valve.

The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter or, in the case of (L.P.) gas, the supply tank, other gas-operated appliances on the same line, etc. Specific information regarding supply line size should be determined by the gas supplier.

Note

Undersized gas supply piping can create a low or ! inconsistent pressure, which will result in erratic

operation of the burner ignition system.

Consistent gas pressure is essential at all gas connections. It is recommended that a 3/4-inch (19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column pressure (W.C.).

Note

A water column (W.C.) test pressure of 3.5 inches

!(8.7 mb) for natural gas and 10.5 inches (26.1 mb) for liquid propane (L.P.) dryers is required at the gas valve pressure tap of each dryer for proper and safe operation.

A 1/8” N.P.T. plugged tap, accessible for a test gauge connection, must be installed in the main gas supply line immediately upstream of each dryer.

Important

Pipe joint compounds that resist the action of natural

!gas and L.P. gas must be used.

Test all connections for leaks by brushing on a soapy water solution (liquid detergent works well).

The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

Note

The dryer must be isolated from the gas supply piping

!system by closing its individual manual shutoff valve

during any pressure test of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).

Warning

!Never test for leaks with a flame!!!

Steam Information _____________________

It is your responsibility to have all plumbing connections made by a qualified professional to ensure that the steam plumbing installation is adequate and conforms with local and state regulations or codes.

Important

Failure to comply with the requirements stipulated

!in this manual can result in component failure,

which will void the warranty.

Note

The dryer is manufactured with a pneumatic ! (piston) damper system, which requires an external supply of air of 0.75 cfh at 80 psi ± 10

psi (0.02 cmh at 5.52 bar ± 0.68 bar]).

Steam Coil pH Level

The normal pH level for copper type steam coils must be maintained between a value of 8.5 to 9.5. For steel type steam coils the pH level must be maintained between a value of 9.5 to 10.5. These limits are set to limit the acid attack of the steam coils.

Important

Coil failure due to improper pH level will void the

!warranty.

Steam Requirements – High Pressure

Inlet: 1” supply line connection, qty. one (1) at top manifold.

Return: 1” return line connection, qty. one (1) at bottom manifold.