SAFETY PRECAUTIONS __________
Warning
For your safety, the information in this manual must
!be followed to minimize the risk of fire or explosion
or to prevent property damage, personal injury, or loss of life.
The dryer must never be operated with any of the back guards, outer tops, or service panels removed. Personal injury or fire could result.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the user smells gas. The instructions should be posted in a prominent location.
What to do if You Smell Gas
•Do not try to light any appliance.
•Do not touch any electrical switch.
•Do not use any phone in your building.
•Clear the room, building, or area of all occupants.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency, or gas supplier.
Dryer(s) must be exhausted to the outdoors.
Although ADC produces a very versatile dryer, there are some articles that, due to fabric composition or cleaning method, should not be dried in it.
Warning
Dry only water washed fabrics. Do not dry articles
!spotted or washed in dry cleaning solvents, a combustible detergent, or “all purpose” cleaner. Explosion could result.
Do not dry rags or articles coated or contaminated with gasoline, kerosene, oil, paint, or wax. Explosion could result.
Do not dry mop heads. Contamination by wax or flammable solvents will create a fire hazard.
Do not use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard.
A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust ductwork, and inside the dryer. The frequency of inspection and cleaning can best be determined from experience at each location.
Warning
The collection of lint in the burner area and exhaust
!ductwork can create a potential fire hazard.
For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the National Electrical Code ANSI/NFPA NO.
LATEST EDITION.
Note
Failure to electrically ground the dryer properly will
!void the warranty.
Under no circumstances should the dryer door switch, lint drawer switch, or the heat safety circuit ever be disabled.
Warning
Personal injury or fire could result should the dryer
!door switch, lint drawer switch, or the heat safety
circuit ever be disabled.
This dryer is not to be used in the presence of dry cleaning solvents or fumes.
Remove articles from the dryer as soon as the drying cycle has been completed.
Warning
Articles left in the dryer after the drying and cooling
!cycles have been completed can create a fire hazard.
Do not operate steam dryers with more than 125 psi (8.6 bar) steam pressure. Excessive steam pressure can cause damage to the steam coil and/or harm personnel.
Replace leaking flexible hoses or other steam fixtures immediately. Do not operate the dryer with leaking flexible hoses. Personal injury may result.
The normal pH level for copper type steam coils must be maintained between a value of 8.5 to 9.5. For steel type steam coils the pH level must be maintained between a value of 9.5 to 10.5. These limits are set to limit the acid attack of the steam coils.
Important
Coil failure due to improper pH level will void the
!warranty.
Read and follow all caution and direction labels attached to the dryer.
For safety, proper operation, and optimum performance, the dryer must not be operated with a load less than
Warning
You must disconnect and lock out the electric supply
!and the gas supply or the steam supply before any
covers or guards are removed from the machine to allow access for cleaning, adjusting, installation, or testing of any equipment per OSHA (Occupational Safety and Health Administration) standards.
Important
Dryer must be installed in a location/environment,
!which the ambient temperature remains between
40º F (4.44º C) and 130º F (54.44º C).
2 | American Dryer Corp. |
|