SPECIFICATIONS/COMPONENT

IDENTIFICATION ________________

Note

ADC reserves the right to make changes in

!specifications at any time without notice or obligation.

Dryer Notes

Ductwork size varies with installation conditions.

!Exhaust static pressure must be no less than 0 and

must not exceed 0.3 inches (0.74 mb) water column.

Steam Dryer Notes

Operating height of steam dryer is 81-inches

!(205.74 cm).

Size of piping varies with installation conditions. Contact factory for assistance.

Steam dryers must be provided with clean, dry, regulated 80 psi + 10 psi (5.5 bar + 0.69 bar) air supply.

Specifications

_________________________

 

 

 

 

 

 

 

 

 

MAXIMUM CAPACITY (DRY WEIGHT)

 

55 lb

 

 

25 kg

TUMBLER DIAMETER

 

 

37”

 

 

94 cm

TUMBLER DEPTH

 

 

 

 

30”

 

76.2 cm

TUMBLER VOLUME

 

 

18.67 cu ft

0.528 cu m

TUMBLER/DRIVE MOTOR

 

 

3/4 hp

 

0.56 kW

DOOR OPENING (DIAMETER)

 

 

31-3/8”

 

79.7 cm

WATER CONNECTION

 

 

 

3/4-11.5 NH

 

DRYERS PER 20’/40’ CONTAINER

 

 

 

10 / 20

 

DRYERS PER 48’/53’ TRUCK

 

 

 

26 / 28

 

 

VOLTAGE AVAILABLE

 

 

120-480v

1,3ø

2,3,4w

50/60 Hz

 

APPROX. NET WEIGHT

 

 

585 lb

 

269.9 kg

Gas

APPROX. SHIPPING WEIGHT

 

645 lb

 

292.6 kg

AIRFLOW

 

 

 

 

600 cfm

 

17 cmm

 

HEAT INPUT

 

 

160,000 Btu/hr

40,320 kcal/hr

 

INLET PIPE CONNECTION

 

 

 

3/4” F.N.P.T.

 

Electric

 

 

OVEN SIZE

 

 

 

 

 

 

30

 

102,400

 

25,800

 

 

 

 

 

 

kW

 

Btu/hr

 

kcal/hr

 

 

 

 

 

 

20

 

68,250

 

17,200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE AVAILABLE

 

 

120-480v

1,3ø

2,3,4w

50/60 Hz

 

APPROX. NET WEIGHT

 

 

625 lb

 

283.5 kg

 

APPROX. SHIPPING WEIGHT

 

675 lb

 

306.2 kg

Steam*

AIRFLOW

 

 

 

 

600 cfm

17 cmm

STEAM CONSUMPTION

 

 

144.7 lb/hr

65.7 kg/hr

 

 

 

 

OPERATING STEAM PRESSURE

 

125 psi max

8.6 bar

 

COMPRESSED AIR CONNECTION

 

 

1/8” F.N.P.T.

 

 

COMPRESSED AIR VOLUME

 

0.75 cfh

 

0.02 cmh

 

BOILER HP (NORMAL LOAD)

 

4.2 Bhp

 

 

 

 

SUPPLY CONNECTION

 

 

1” F.N.P.T.

 

 

 

RETURN CONNECTION

 

 

1” F.N.P.T.

 

 

Shaded areas are stated in metric equivalents

 

 

 

12/01/04

*Specify air-operated steam damper system or electromechanical steam damper system when

ordering. Air-operated steam damper system must be provided with a clean, dry, regulated 80 psi ± 10 psi (5.52 bar ± 0.68 bar). Air connection is 1/8” N.P.T. Air volume requirement is 0.75 cfh (0.02 cmh).

113345-9

www.amdry.com

3

Page 5
Image 5
American Dryer Corp ML-55II installation manual Specifications/Component